Terminal blocks for connection of inputs and outputs

Mounting 

The device has degree of protection IP10, and is there-

fore suitable for use in dry interior rooms. The housing is 

made for rail mounting according to EN 60715 in boards 

or cabinets for electrical distribution. The correct mounting 

is when the DC inputs screw terminal is located at the bot-

tom. When installing be sure to leave accessible only the 

front panel; all other sides must not be accessible. For the 

mounting proceed as follows:
•  with the aid of a tool bring the locking device in the fully 

lowered position (a);

• 

place  the  upper  edge  of  the  rear  inner  profile  on  the 

upper edge of the rail (b);

•  rotate the device towards the rail (c);
•  push the locking device upward until it stops (d).

Note. 

When mounting the device in boards and ca-

binets it shall be provided the necessary ventilation 

so that the temperature can be kept within the ope-

rating range of the device.

i

a

b

d

c

1)  Screw terminal for 12/24/48 Vdc input and output loads

2)  Screw terminal for local commands and DALI line connection

3)  Signalling LED

-

-

OUT

L-

Dimmer LED

EK-GH1-DL

DC In: 12-48V

Out: max 8A

DALI IN

DA DA

DA DA

DALI OUT

1

2

3

Nr.

Mark

Connection

1-3

+

DC (+) input

2-4

-

DC (-) input

5

L+

Output (+)

6

L-

Output (-)

Nr.

Mark

Connection

1-2

INPUT IN-0V

N.O. Pushbutton input, analogic input or 

potentiometer

3

DA-DALI IN

DALI pole 1

6

DA-DALI OUT

4

DA-DALI IN

DALI pole 2

7

DA-DALI OUT

5-8

-

Not used

Before removing the device, be sure that inputs, outputs, 

and the DC power supply have been disconnected. Use a 

screwdriver to slide down the locking device and remove 

the device from the rail.

Summary of Contents for EK-GH1-DL

Page 1: ...5 Brightness adjustment up to full off Dim to Dark Minimum brightness level 0 1 1 in push D PWM Modulation Adjusting D PWM frequency 300 600 1200 Hz Adjusting output curve Linear Quadratic Exponential Soft start and soft stop Technical data Inputs Input constant voltage 12 24 48 Vdc Supply voltage min 10 8 Vdc max 52 8 Vdc Power absorbed while awaiting command 500 mW Dimming Dimming frequency D PW...

Page 2: ... push the locking device upward until it stops d Note When mounting the device in boards and ca binets it shall be provided the necessary ventilation so that the temperature can be kept within the ope rating range of the device i a b d c 1 Screw terminal for 12 24 48 Vdc input and output loads 2 Screw terminal for local commands and DALI line connection 3 Signalling LED OUT L Dimmer LED EK GH1 DL ...

Page 3: ...ve settings Default Exponential Quadratic Linear Switches 3 4 input local command settings Command Description Connection Configuration Pushbutton N O pushbutton without memory N O pushbutton with memory 0 10 V Analog input 0 10V 1 10 V Analog input 1 10V or Potentiometer Switches 5 6 output dimming frequency settings 300 Hz 600 Hz 1200 Hz Reserved DALI bus line and command connections The connect...

Page 4: ...t then insert a protection against over current between the power supply and the device Characteristics of the supply and LEDs terminal block Screw tightening of the conductors Power LEDs wiring 2 5mm2 solid 1 5 mm2 stran ded 30 12 AWG Power and LEDs stripping recommended approx 7 5 mm Max torque 0 5 Nm Outputs The length of the connection cables between the product and the LED module must be less...

Page 5: ...ectromagnetic Compatibility Directive 2014 30 EU and the RoHS 2 Directive 2011 65 UE Reference Standards EN 61347 1 2008 A1 2011 A2 2013 EN 61000 2014 3 2 EN 61000 2013 3 3 EN 62384 2006 A1 2009 EN 55015 2013 A1 2015 EN 61547 2009 EN 50581 2012 Maintenance The device is maintenance free To clean use a dry cloth It must be avoided the use of solvents or other aggressive substances Disposal At the e...

Page 6: ...al support at the e mail address support ekinex com or visit the website www ekinex com Each ekinex device has a unique serial number on the label The serial number can be used by installers or system integrators for documentation purposes and has to be added in each communication addressed to the EKINEX technical support in case of malfunctio ning of the device KNX and ETS are registered trademar...

Reviews: