background image

6

•  ekinex® defective devices must be returned to the ma-

nufacturer at the following address: Ekinex S.p.A. Via 

Novara 35, I-28010 Vaprio d’Agogna (NO) Italy

Other information

•  The instruction sheet must be delivered to the end cu-

stomer with the project documentation

•  For further information on the product, please contact 

the ekinex® technical support at the e-mail address: 

support@ekinex.com or visit the website www.ekinex.

com

•  Each ekinex® device has a unique serial number on 

the label. The serial number can be used by installers 

or system integrators for documentation purposes and 

has to be added in each communication addressed to 

the EKINEX  technical support in case of malfunctio-

ning of the device

•  KNX® and ETS® are registered trademarks of KNX As-

sociation cvba, Brussels

© EKINEX S.p.A. The company reserves the right to make changes to this 

documentation without notice.

Summary of Contents for EK-GH1-DL

Page 1: ...5 Brightness adjustment up to full off Dim to Dark Minimum brightness level 0 1 1 in push D PWM Modulation Adjusting D PWM frequency 300 600 1200 Hz Adjusting output curve Linear Quadratic Exponential Soft start and soft stop Technical data Inputs Input constant voltage 12 24 48 Vdc Supply voltage min 10 8 Vdc max 52 8 Vdc Power absorbed while awaiting command 500 mW Dimming Dimming frequency D PW...

Page 2: ... push the locking device upward until it stops d Note When mounting the device in boards and ca binets it shall be provided the necessary ventilation so that the temperature can be kept within the ope rating range of the device i a b d c 1 Screw terminal for 12 24 48 Vdc input and output loads 2 Screw terminal for local commands and DALI line connection 3 Signalling LED OUT L Dimmer LED EK GH1 DL ...

Page 3: ...ve settings Default Exponential Quadratic Linear Switches 3 4 input local command settings Command Description Connection Configuration Pushbutton N O pushbutton without memory N O pushbutton with memory 0 10 V Analog input 0 10V 1 10 V Analog input 1 10V or Potentiometer Switches 5 6 output dimming frequency settings 300 Hz 600 Hz 1200 Hz Reserved DALI bus line and command connections The connect...

Page 4: ...t then insert a protection against over current between the power supply and the device Characteristics of the supply and LEDs terminal block Screw tightening of the conductors Power LEDs wiring 2 5mm2 solid 1 5 mm2 stran ded 30 12 AWG Power and LEDs stripping recommended approx 7 5 mm Max torque 0 5 Nm Outputs The length of the connection cables between the product and the LED module must be less...

Page 5: ...ectromagnetic Compatibility Directive 2014 30 EU and the RoHS 2 Directive 2011 65 UE Reference Standards EN 61347 1 2008 A1 2011 A2 2013 EN 61000 2014 3 2 EN 61000 2013 3 3 EN 62384 2006 A1 2009 EN 55015 2013 A1 2015 EN 61547 2009 EN 50581 2012 Maintenance The device is maintenance free To clean use a dry cloth It must be avoided the use of solvents or other aggressive substances Disposal At the e...

Page 6: ...al support at the e mail address support ekinex com or visit the website www ekinex com Each ekinex device has a unique serial number on the label The serial number can be used by installers or system integrators for documentation purposes and has to be added in each communication addressed to the EKINEX technical support in case of malfunctio ning of the device KNX and ETS are registered trademar...