17
15
Motor Temp Hot
Cutback
1. The motor temperature reaches or exceeds the alarm temperature
set by the program, resulting in the reduction of current output
2. The motor temperature parameters are incorrectly set
3. If the motor does not use a temperature sensor, program
parameters "Temp Compensation" and "Temp"
Cutback must be set to OFF.
16
Motor Temp Sensor
Fault
1. The motor temperature sensor is incorrectly connected
If the motor does not use a temperature sensor, the programming
parameters are "Temp Compensation and Temp"
Cutback must be set to "OFF"
17
Coil 1 Driver
Open/Short
1. Connect load open or short
2. The connecting pin is defiled
3. Wrong wiring
18
Main Open/Short
1. Connect load open or short
2. The connecting pin is defiled
3. Wrong wiring
19
Coil2 Driver Open/Short
1. Connect load open or short
2. The connecting pin is defiled
3. Wrong wiring
20
EMBrake Open/Short
1. Connect load open or short
2. The connecting pin is defiled
3. Wrong wiring
21
Coil3 Driver Open/Short
1. Connect load open or short
2. The connecting pin is defiled
3. Wrong wiring
22
Coil4 Driver Open/Short
1. Connect load open or short
2. The connecting pin is defiled
3. Wrong wiring
23
PD Open/Short
1. Connect load open or short
2. The connecting pin is defiled
3. Wrong wiring
24
Encoder Fault
1. Motor encoder failure
2. Wrong wiring
25
Motor Open
1, motor phase deficiency
2. Wrong wiring
26
Main Contactor Welded
1, main contactor contact fusion
2. Motor U or V is disconnected or phase is missing
3. The circuit charging capacitor connected to the B+ terminal exists
27
Main Contactor Did Not
Close
1. The main contactor is not closed
2, the main contactor contact oxidation, melting
Or the connection status is unstable
3. The capacitor is charged by external devices
4. The fuse is disconnected
28
Throttle Wiper High
1, accelerator potentiometer output voltage is too high