18
29
Throttle Wiper Low
1, accelerator potentiometer output voltage is too low
30
Pot2 Wiper High
1, potentiometer 2 output voltage is too high
31
Pot2 Wiper Low
1, potentiometer 2 output voltage is too high
32
Pot Low Over current
1, potentiometer impedance is too low
33
EEPROM Failure
EEPROM
1. Failed to write to the EEPROM storage.This may be caused by VCL
writing to EEPROM storage, or by CAN BUS, or by a parameter error
programmed into the controller after the programmer parameters are
adjusted.
34
HPD/Sequencing Fault
1. Incorrect setting of key start, interlock, direction and accelerator input
sequence.
2, wiring, switch key, interlock, direction, or accelerator input failure
35
Emer Rev HPD
1. The emergency reverse operation has ended, but the accelerator,
forward and reverse input and interlock have not been reset
。
36
Parameter Change Fault
1. In order to ensure the safety of the vehicle, the modification of some
specific parameters must take effect after the key switch is restarted.
38
VCL Run Time Error
1. The VCL code timed out
39
External Supply Out of
Range
1, the external load in 5V and 12V power source current is too
large or too small
Checking Menu parameters are incorrect, for example, ExtSupply
Max, Ext
Named "Supply" Min"
40
OS General
1. The internal controller fails
41
PDO Timeout
1. The CAN PDO message receiving time exceeds the PDO time
limit
42
Stall Detected
1. Motor blocking
2. Motor encoder failure
3. Wrong wiring
4. Power supply of the input motor encoder is faulty
43
Motor Characterization
Fault
1, in the motor matching process of modern code comparison:
0 = normal
1= The controller receives the encoder number,
But the impulse quantity is undefined. Please hand set
Buy pulse value
2= Motor temperature sensor failure
3= High temperature reaction failure of motor
4= motor overheating reaction failure
5= Low temperature reaction failure of motor
6= low voltage response failure
7= high pressure reaction failure
8= The controller cannot detect the encoder message
Alpha, channel signal is down
9= Motor parameter setting exceeds the range
44
Motor Type Fault
1. The motor type parameter value is out of range
45
VCl/OS Mismatch
1. The VCL program in the controller does not match the OS