DK50
DK50
PLUS
NP-DK50-3_07-2014-md
- 36 -
7/2014
Fig.14
3
Fig.13
1
2
14.4. Replacement of filter element in filter
(Fig.12)
Loosen a safety-catch (1) on a filter regulator by pulling it down.
Turn the container slightly (2) and pull out.
Unbolt the filter holder (3).
Change the filter bed (4), bolt the filter holder.
Put the filter container on and secure it by turning it until the safety-
catch is fixed.
Filter
Order number
Filter insert
Order number
AF 30-F02C
025200005
AF 30P-060S 5
m 025200061
14.5. Replacement of filter element in micro-filter
(Fig.13)
Loosen a safety-catch (1) on a micro filter by pulling it down.
Turn the container slightly (2) and pull out.
Unbolt the filter (3).
Change and bolt the filter bed.
Put the filter container on and secure it by turning it until the safety-
catch is fixed.
14.6. Replacement of filter in condensation and filtration unit
Before beginning, depressurize the air tank to zero and
disconnect the appliance from the mains.
(Fig.14)
In the case of a regular operation of a condensation unit it is necessary to
replace the filter inside the filter with automatic desludging.
Release a safety lock (1) on the filter vessel by its pulling downwards, slightly
rotate the filter cover (2) to the left and take it out.
Unscrew the filter holder (3) by its rotation to the left.
Replace the filter and fix the new one by rotation of the holder to the right
back on the filter body.
Replace the filter cover and secure it by turning to the right until the safety
pin locks.
15. STORAGE
If the compressor will not be used for a prolonged time period, drain any condensate from the air tank. Then
turn on the compressor for 10 minutes, keeping the drain valve open (1) (Fig.9, Fig.10). Switch off the
compressor by switch (3) at pressure switch (2) (Fig.8), close the drain valve and disconnect the appliance
from the mains.
16. DISPOSING OF THE APPLIANCE
• Disconnect the appliance from the mains.
• Release air pressure in the pressure tank by opening the drain valve (1) (Fig.9, Fig.10).
• The components of the product are non-toxic.
• Dispose of the appliance following all environmental regulations.
Micro-filter
Order number
Filter insert
Order number
AFM 30-F02C
025200007
AFM 30P-060AS 0,3
m 025200076
1
2
4
3
Fig.12
Summary of Contents for DK50 2V/110
Page 1: ......
Page 2: ......
Page 130: ...ROZSAH DODÁVKY PARTS LIST ОБЪЕМ ПОСТАВКИ LIEFERUMFANG COMPOSITION DU LOT PRZEDMIOT DOSTAWY ...
Page 131: ......
Page 132: ......
Page 133: ...No text on the page ...
Page 134: ...No text on the page ...
Page 135: ...No text on the page ...