DK50 2V/50
DK50 4VR/50
03/2013
- 19 -
NP-DK50 2V50-4VR50-5_03-2013.doc
15.5.
Replacement of the buoy in the water separator
(Fig.13)
During regular operation of drier is necessary to change the buoy in the water separator.
A) Release pressure.
B) Dismount separator container.
C) Pull out condenser separator
D) Release nut of the buoy placed in the bottom part of the container.
E) Pull out worn buoy of the separator and replace it for the new one.
F) Secure the buoy with the nut in bottom part of the container.
G) Place the condenser separator back as shown in the picture.
H) Container of the separator insert back and screw in.
I) The container is definitely secured in the point of the symbol.
Fig.13
Water separator
Order number
Buoy
Order number
WS010BBFX 025200119
EF1
025200146
16. STORAGE
If the compressor will not be used for a prolonged time period, drain any condensate from the air tank. Then
turn on the compressor for 10 minutes, keeping the drain valve open (1) (Fig.9). Switch off the compressor
by switch (3) at pressure switch (2) (Fig.8), close the drain valve and disconnect the appliance from the
mains.
17. DISPOSING OF THE APPLIANCE
• Disconnect the appliance from the mains.
• Release air pressure in the pressure tank by opening the drain valve (1) (Fig.9).
• The components of the product are non-toxic.
• Dispose of the appliance following all environmental regulations.
A
B
C
D
E
F
G
H
I
Summary of Contents for DK50 2V/50
Page 1: ......
Page 2: ......
Page 3: ...CONTENTS 3 INHALT 20 38 OBSAH 57 Ed 5...
Page 22: ......
Page 43: ...DK50 2V 50 DK50 4VR 50 03 2013 41 NP DK50 2V50 4VR50 5_03 2013 doc 1 CE CE 93 42 EEC 2 2 1 2 2...
Page 44: ...DK50 2V 50 DK50 4VR 50 NP DK50 2V50 4VR50 5_03 2013 doc 42 03 2013 2 3 3 CE...
Page 49: ...DK50 2V 50 DK50 4VR 50 03 2013 47 NP DK50 2V50 4VR50 5_03 2013 doc 4 8 5 C 40 C 70 5 9...
Page 61: ...DK50 2V 50 DK50 4VR 50 03 2013 59 NP DK50 2V50 4VR50 5_03 2013 doc O...
Page 84: ......