INSTALLATION
11. CONDITIONS FOR USE
The compressor may only be installed and
operated in dry, well-ventilated and dust-free
areas.
The compressor must be installed so that it is
accessible at all times for operating and
maintenance. Please ensure that the
nameplate on the device is readily accessible.
The compressor must stand on a flat,
sufficiently stable base (be aware of the
weight of the compressor, see Technical
Data).
The compressor on the operator’s side must
be at least 70 cm from the wall to allow air
flow for cooling purposes and to ensure the
safety of the operator and maintenance
personnel.
Operating the equipment in areas in
which flammable mixtures may be
present is prohibited, such as in
operating rooms, coal storage areas,
etc. Flammable materials pose an
explosion hazard.
Replace all damaged electrical cords
and air hoses immediately.
The power cord may not show signs of
stress and must be kept without
tension (putting any objects on it is
prohibited) and subjecting the cord to
external heat in any form is prohibited.
Environmental requirements:
Temperature:
+0°C to +40°C,
Max. relative humidity:
70%,
Max. absolute humidity:
15 g/m
3
.
Approximately 70% of the electrical energy
used by the compressor air pumps is
converted to heat and therefore the rooms in
which a compressor assembly is installed
must have additional ventilation to provide
sufficient air exchange for cooling purposes
(see the technical data)
Caution! Hot surface!
Portions of the
compressor air pump may be hot and
reach hazardous temperatures during
compressor operations that may harm
materials or operating staff.
Fire hazard!
Fig. 4 - Air outlet
Cooling air inlet
Recommended flow
of cooling air:
DK50 3x4VR/M - 1850
m3/h
Applies for continuous
operation and cooling air
temperature of 20°C
Space conditionsTemperature
+5°C
÷
+40°C
Relative humidity 70%
Compressed air outlet