DK50 3x4VR/M 

NP-DK50-3x4VRM_ED-EN-2_10-2018 

                                   - 8 - 

10/2018

 

6.  TECHNICAL DATA 

Compressors  are  designed  for  dry  and  well-
ventilated  indoor  environments  with  the 
following conditions: 

Temperature:   

 

 

 

+0°C to +40°C,  

Max. relative humidity: 

 

70%,  

Max. absolute humidity:   

15 g/m

3

 
Tab. 1 

Type

 

DK50 3x4VR/M 

Output at 6 bar 

l/min 

800 

Voltage / frequency

 

V / Hz

 

3 x 400 / 50

 

power / max./

 

 15 

Main circuit protection 
device rating 

16/B 

Main electrical feeder 

mm2 

1.5 mm2 

Enclosure 

 

IP10 

Air tank capacity   

 

290 

Working pressure 

 

bar 

 8 

Safety valve     

bar 

10 

Noise level  

dB 

 80 

Total weight of compressor 
(net)  

kg 

 337 

Weight - compressor 

kg 

 279 

Weight - dryer 

kg 

58 

Total compressor 
dimensions 
(W x D x H)  

mm 

2850x800x1040 

Dimensions - compressor  
(W x D x H)   

mm 

1780x800x1025 

Dimensions - ED72 dryer 
(W x D x H)  

 

mm 

760x550x1040 

Operating mode 

 

S1 – 100% 

Dryer performance (PDP*) 
with condensing dryer 
(ED72) 

 

+3°C 

Time to fill air tank  
(from 0 to 7 bar) 

140 

Required cooling air 
changes in space 

m3/h 

1850 

Electrical class 

 

Class I. 

 
(*) Apply the correction factor for the ED72 dryer 

Summary of Contents for DK50-3X4VR/M

Page 1: ...User manual EN DK50 3X4VR M...

Page 2: ...October 2018 Z_2195 2018 Chap 2 pgs 5...

Page 3: ...RM_ED EKOM spol s r o Priemyseln 5031 18 SK 921 01 Pie any Slovak Republic tel 421 33 7967255 fax 421 33 7967223 www ekom sk email ekom ekom sk DATE OF LAST REVISION 10 2018 NP DK50 3x4VRM_ED EN 2_10...

Page 4: ...UMATIC SCHEMATIC 13 OPERATION 14 10 TURNING THE COMPRESSOR ON 14 INSTALLATION 18 11 CONDITIONS FOR USE 18 12 PLACEMENT OF THE COMPRESSOR 19 13 COMPRESSED AIR CONNECTIONS 20 14 ELECTRICAL CONNECTIONS 2...

Page 5: ...oduct The manufacturer only guarantees the safety reliability and function of the equipment if installation new settings changes modifications and repairs are performed by the manufacturer or its repr...

Page 6: ...nings The equipment may only be connected to a properly installed socket connected to earth grounded Before the product is plugged in make sure that the mains voltage and frequency stated on the produ...

Page 7: ...protects the equipment from damage during transport The original compressor packaging must be used for transport whenever possible The compressor is shipped in a vertical position and must be secured...

Page 8: ...lectrical feeder mm2 1 5 mm2 Enclosure IP10 Air tank capacity l 290 Working pressure bar 6 8 Safety valve bar 10 Noise level dB 80 Total weight of compressor net kg 337 Weight compressor kg 279 Weight...

Page 9: ...ion factor for working pressure p bar 4 5 6 7 8 9 10 FC1 0 78 0 85 0 93 1 0 1 06 1 11 1 15 Correction factor for temperature of compressed air entering the dryer tinlet C 30 35 40 45 50 55 FC2 1 2 1 0...

Page 10: ...lean oil free compressed air to power individual devices and equipment with compressed air used in large dental clinics and laboratories in hospital wards and other settings where the parameters and p...

Page 11: ...air to power pneumatic devices and equipment used in large dental clinics and laboratories hospital wards etc Compressor air pumps 1 draw in atmospheric air through the inlet filters 8 and compress it...

Page 12: ...6 Pressure gauge 7 Condensate drain valve 8 Inlet filter 9 Solenoid relief valve 10 Dryer cooler 11 ED dryer 12 Pressure relief valve 13 Water separator 14 Condensate drain kit 15 Adjustable foot 16 S...

Page 13: ...EMATIC Legend 1 Inlet filter 11 Cooler 2 Air pump 12 Cooler fan 3 Fan 13 Water separator 4 Relief valve 14 Pressure relief valve 5 Safety valve 15 Condensate drain valve 6 Check valve 16 ED dryer 7 Pr...

Page 14: ...dryer may be shut off by pressing and holding the ON OFF button again for 1 second The dryer motors then switch off to ensure the space inside the dryer itself cools down and the internal pressure bal...

Page 15: ...y pressing ESC once the maintenance work is completed 10 1 2 Alarms The equipment has an intelligent monitoring system that generates an alarm signal based on priority medium priority alarms have high...

Page 16: ...peration is shown once the malfunction is remedied and the motor circuit breaker is manually placed back in the ON position The compressor only supplies compressed air to the central line through the...

Page 17: ...nufacturer s technical support for such purposes Web server The controller has an integrated Web Server function that facilitates compressor monitoring via a PC smartphone or tablet using a convention...

Page 18: ...e all damaged electrical cords and air hoses immediately The power cord may not show signs of stress and must be kept without tension putting any objects on it is prohibited and subjecting the cord to...

Page 19: ...e compressor and dryer module to the pallet 12 1 Handling Use a fork lift truck or similar hoisting equipment to handle and position the product Position the compressor module at the site of installat...

Page 20: ...or assembly using the hoses included with delivery Fig 7 Connect the hoses from the water separator and the condensate drain from the dryer to connectors at the canister valves Fig 8 A G1 2 female thr...

Page 21: ...otection for the equipment per the specifications in valid technical standards The product is delivered without a power cord Connect the compressor module to the dryer module using the W22 cable Fig 1...

Page 22: ...s then switch off to ensure the space inside the dryer itself cools down and the internal pressure balances The dryer begins cooling the heat exchanger Wait for 5 minutes this time is shown in the bot...

Page 23: ...compressor from power Vent the air tank by disconnecting from the central compressed air circuit and opening the outlet valve Fig 1 or the air tank drain valve Attention Power terminals X0 remain ene...

Page 24: ...00 8000 10000 12000 Chapter Set of replacement parts Performed by Product function check x 18 2 user Clean dryer filter grid Inspect the condensate drain and check temperatures on the display x See th...

Page 25: ...chnician Check safety valve operation x x x x chapter 18 6 qualified technician Check solenoid valve operation x x x See the service manual qualified technician Air pumps intake filter replacement x x...

Page 26: ...reseal the connectionwhere leaks are found Equipment inspection Fig 1 Check the condition of the compressor air pump for normal operation and noise levels Check the operation of fans Check the condit...

Page 27: ...ses when venting any air Rotate the screw on the safety valve to the left a number of turns until the valve itself vents Let the safety valve vent for only a few seconds Rotate the screw back to the r...

Page 28: ...ir circuit exceeds its pre set value The pressure relief valve 1 closes as the pressure drops Fig 15 Pressure in the compressed air circuit can only increase because of an increase in flow resistance...

Page 29: ...chboard tighten Check the primary power connection replace if damaged Problem with electrical power source Main breaker is off Controller or expansion module malfunction Replace failed controller or e...

Page 30: ...in service Once the dryer malfunction is remedied and it is reconnected the condensate trapped in the air tank must be drained and the air tank must be dried The manufacturer reserves the right to ma...

Page 31: ...on off controls controlprocedures data on the display panel alarms operation in alarm conditions Y N N C Installation connection to equipment Y C Productmaintenance maintenanceintervals maintenancepr...

Page 32: ...DK50 3x4VR M 10 2018 32 NP DK50 3x4VRM_ED EN 2_10 2018 mark with an X in points 5 and 6 Y yes N no Enter any observations from points 5 and 6 into the Notes section...

Page 33: ...el e ma NP D 11200 DK50 M spol s r o 01 PIE ANY 421 33 79672 ail ekom eko DK50 3x4VRM 00284 0001 0 3X4 Priemyseln Y Slovak Repu 255 fax 421 om sk www e M_ED EN 2_1 4VR 5031 18 ublic 1 33 7967223 kom s...

Reviews: