DK50 4VR/50
04/2018
- 25 -
NP-DK50 4VR50-11_04-2018
15.9. Clean the cooler ribs and the fan
For permanently high efficiency, it is necessary to maintain the whole equipment and especially the cooler´s
fan and the cooler itself clean – 1x year suck or blow settled dust out with compressed air from the surface of
the cooling ribs and the fan.
16.
STORAGE
If the compressor will not be used for a prolonged time period, drain any condensate from the air tank. Then
turn on the compressor for 10 minutes, keeping the drain valve open (1) (Fig.10). Switch off the compressor
by switch (3) at pressure switch (2) (Fig.9), close the drain valve and disconnect the appliance from the
mains.
17.
DISPOSING OF THE APPLIANCE
• Disconnect the appliance from the mains.
• Release air pressure in the pressure tank by opening the drain valve (1) (Fig.10).
• The components of the product are non-toxic.
• Dispose of the appliance following all environmental regulations.
18.
REPAIR SERVICE
Guaranteed and post-guarantee repairs must be done by the manufacturer, its authorized representative, or
service personnel approved by the supplier.
The manufacturer reserves the right to make changes to the appliance without notice. Any changes made
will not affect the functional properties of the appliance.
19.
SOLVING PROBLEMS
Caution! Before proceeding, depressurize the air tank to zero and disconnect the
appliance from the mains.
The internal surfaces of the air tank must be cleaned and all condensed liquid must be removed after a dryer
failure.
Check the dew point of the air leaving the air tank (see Chapter 5 - Technical Data) in order to protect
connected equipment from damage!