DK50 9x4VRT/M
10/2018
NP-DK50-9x4VRTM_ED-EN-2_10-2018
- 25-
Note:
1. The values of time-based variables are
displayed in minutes. For instance,
12.000 minutes is displayed in address
ten, which corresponds to 2.000 hours.
2. The values of analogue parameters
(pressures and temperatures) are
displayed without decimal points
Logging out of the web server
Click on the button in the upper left corner.
OPERATION
IN
CASE
OF
EMERGENCY,
DISCONNECT THE COMPRESSOR
FROM THE MAINS (TURN OFF THE
MAIN SWITCH).
THE COMPRESSOR AIR PUMP
HAS HOT SURFACES. BURNS
MAY RESULT IF CONTACT IS
MADE.
During prolonged operation of the
compressor,
the
temperature
inside the enclosed model may
increase to over 40°C. At this point
the cooling fan in the enclosure
and
the
compressor
fan
automatically switch on. The fans
switch off automatically once the
space is cooled to below 32°C.
Automatic start. The compressor
automatically switches on when
pressure in the air tank drops to
the pressure switch’s lower limit
level.
The
compressor
automatically switches off after
reaching the pressure switch’s
upper limit level.
15. INITIAL START UP OF THE DEVICE
Make sure all transport stabilizers were
removed.
Check that all compressed air hose
connections are correct.
Check to ensure the power cord is properly
connected to the mains.
Check to ensure the outlet valve is in the
OFF position.
16. SWITCHING THE COMPRESSOR ON
(Fig.1 - 3 )
Turn the main switch (19) into the “I”
position
on
the
compressor
switchboard. The white indicator P1
(17) lights up and the display (16) on
the switchboard door shows the
following message:
DRYER: the dryer model - ED180
HOURS RUN: operating hours
PRESSURE: current pressure
REMAIN. TIME: the time remaining until the
compressor switches on (300 seconds).
Dryer - ED180
Press and hold the ON/OFF button on
the dryer panel for 1 second. The dryer
motors then gradually start.
The dryer may be shut off by pressing
and holding the ON/OFF button again
for 1 second. The dryer motors then
switch off to ensure the space inside
Summary of Contents for DK50 9x4VRT/M
Page 1: ...DK50 9x4VRT M User manual EN...
Page 2: ...October 2018 Z_2195 2018 Chap 3 pgs 5...
Page 22: ...DK50 9x4VRT M NP DK50 9x4VRTM_ED EN 2_10 2018 22 10 2018 Fig 13 Fig 14 Fig 15 Cable bridge...
Page 42: ...DK50 9x4VRT M NP DK50 9x4VRTM_ED EN 2_10 2018 42 10 2018 ANNEX 22 MAPPING PARAMETERS...
Page 43: ...DK50 9x4VRT M 10 2018 NP DK50 9x4VRTM_ED EN 2_10 2018 43...