DK50 9x4VRT/M
NP-DK50-9x4VRTM_ED-EN-2_10-2018 - 36 -
10/2018
18.8. Cleaning / replacing the
compressor’s intake filters (*)
(Fig. 21, Fig. 22)
(*) - only applicable to enclosed products.
Clean or replace the inlet filters at defined
intervals (Table 3) using the following
procedure:
Remove the nuts (1) and covers (4) on
the lower part of the enclosure beneath
the air pumps two times and remove
the filters (5).
Remove the nuts (1) and covers (2)
inside the enclosure three times and
remove the filters (3).
Clean or wash the filter if heavily
contaminated in a solution of soapy
water and allow to dry completely.
Reinstall the filters once dry (reverse
the procedure to reassemble).
In Point A, remove the foam, remove the 4
screws (5), washers (6) and remove the
suction filter cover (7). – (Fig. 21)
Remove the 2 nuts (8) on the filter bracket
(9) and remove the filter (10).
In Point B (on the sides (11)), remove the 2
nuts (12), washers (13), release the filter
bracket (14) and remove the filter (15).
Clean or wash the filter, if heavily
contaminated, in a solution of soapy water
and allow to dry completely.
Reinstall the filters once dry (reverse the
procedure to reassemble
).
A
B
C
D
E
F
G
H
I
Fig .20
Summary of Contents for DK50 9x4VRT/M
Page 1: ...DK50 9x4VRT M User manual EN...
Page 2: ...October 2018 Z_2195 2018 Chap 3 pgs 5...
Page 22: ...DK50 9x4VRT M NP DK50 9x4VRTM_ED EN 2_10 2018 22 10 2018 Fig 13 Fig 14 Fig 15 Cable bridge...
Page 42: ...DK50 9x4VRT M NP DK50 9x4VRTM_ED EN 2_10 2018 42 10 2018 ANNEX 22 MAPPING PARAMETERS...
Page 43: ...DK50 9x4VRT M 10 2018 NP DK50 9x4VRTM_ED EN 2_10 2018 43...