DK50 9x4VRT/M
10/2018
NP-DK50-9x4VRTM_ED-EN-2_10-2018
- 37-
18.9. Compressor performance check
Turn off the compressor using the STOP
button
Vent the air pressure in the air tank to zero
Turn on the compressor using the START
button
Measure the time to fill the air tank from 0
to 7 bar
The measured value must be less than the
data provided in the “Technical data” table
18.10. Check operation of check valves
Compressed air circuit:
Check for proper operation of the check
valves (3) in the pneumatic circuit by
disconnecting the pressure hoses from the air
pumps.
One air pump must be operating,
shut off the remaining air pumps
at the current protection device in
the switchboard. No air may leak
through the check valves.
Fig .21
Fig. 22