DK50 9x4VRT/M
10/2018
NP-DK50-9x4VRTM_ED-EN-2_10-2018
- 41-
one another switch on
(overheating)
enclosure cooling fans do not operate
Defective temperature switch – replace
ED180 dryer
See the dryer manual on the CD
High compressed air
dew point
Condensation dryer off
Turn on the dryer,
drain condensate found in the air tank
Dryer malfunction
Call in professional service
Once a fault is cleared and after reassembling
the dryer, all condensate trapped in the air
tank must be drained off, the air tank must be
dried and the dryer must be regenerated, best
when using continuous compressor operation
at a pressure of around 0.7 bar for a period of
at least 1 hour; then check the dryness of the
compressed
air.
20. REPAIR SERVICE
Guaranteed and post-guarantee repairs must
be done by the manufacturer, its authorized
representative, or service personnel approved
by the supplier.
The manufacturer reserves the right to
make changes to the device without
notice. Any changes made will not affect
the functional properties of the device.
21. DISPOSAL OF THE DEVICE
Disconnect the appliance from the mains.
Release air pressure in the pressure tank
by opening the drain valve (12) (Fig. 2).
Dispose of the equipment following all
applicable environmental regulations.
Entrust a specialised company to sort and
dispose of waste.
Worn out components have no negative
environmental impact
Summary of Contents for DK50 9x4VRT/M
Page 1: ...DK50 9x4VRT M User manual EN...
Page 2: ...October 2018 Z_2195 2018 Chap 3 pgs 5...
Page 22: ...DK50 9x4VRT M NP DK50 9x4VRTM_ED EN 2_10 2018 22 10 2018 Fig 13 Fig 14 Fig 15 Cable bridge...
Page 42: ...DK50 9x4VRT M NP DK50 9x4VRTM_ED EN 2_10 2018 42 10 2018 ANNEX 22 MAPPING PARAMETERS...
Page 43: ...DK50 9x4VRT M 10 2018 NP DK50 9x4VRTM_ED EN 2_10 2018 43...