Pellet burner GP xx sc 29
6.4.
STOPPING THE OPERATION OF A PELLET BURNER FROM SERIES „GP XX
SC”.
Stopping the burner operation can be performed through the control module, which submits
command for operation of the burner. Restoring of the burner’s operation can be performed
through changing the control module’s adjustment.
6.4.1 STOPPING THE OPERATION OF A PELLET BURNER FROM SERIES „GP XX
SC” THROUGH THE SWITCH “START”.
Through the button “START” (which has to be installed by the servicing technician during the
burner mounting and in accordance with the attached wiring diagram) the burner can be
started to operational mode and respectively can be switched OFF. When switching the
burner OFF its display panel shows a message “
FINAL COMBUSTION
”.
The burner switching OFF must be performed only through the switch “START”
and not through stopping the appliance’s power supply. The reason is because
through the switch “START” the burner performs controlled stopping, which
includes cooling of the appliance and complete fuel combustion, as this process
preserves the appliance’s reliability.
6.4.2. STOPPING THE OPERATION OF A PELLET BURNER FROM SERIES „GP XX
SC” THROUGH A MENU FROM ITS COTROLLER KEYBOARD.
The following actions have to be performed in order to stop the burner’s operation:
Press and hold the button “ESC” (for more than 5 seconds);
Choose the answer “YES” when the display shows -
”Make final combustion?“
.
When the choice for stopping is confirmed a message
”Final combustion”
is shown on the
display panel and the burner performs stopping procedure.
There is also another method for stopping the burner’s operation: through the menu ”
MAKE
FINAL COMB.”
from the burner’s controller.
This option is used to stop the pellet burner’s operation by performing final
combustion of the fuel, located on the burner’s fire-grate.