/ 23 /
RECOMMENDED FILLING AND LEAK-
TESTING PROCEDURE
STEP 1
It is mandatory to do the following:
1. Disconnect all PSU power connectors (4/8-pin ESP, 24-pin ATx,
PCI-express power, SATA power) in your computer.
2. Plug the EK-ATx Bridging plug (enclosed) to your 24-pin ATx PSU
cable which allows jump starting your computer.
3. Connect the EK-Cable Pump Testing Adapter’s SATA power header
to your vacant SATA power connector on your PSU (see picture un-
der STEP2 for explanation)
This procedure requires only the pump to be connected to the power sup-
ply (PSU). Everything else needs to be disconnected!
STEP 2
Plug the EK-ATx Bridging plug (enclosed) to your 24-pin ATx PSU cable
to jump start your computer.
Connect the PSU SATA power connector to the female SATA power
header from the pump testing adapter.
STEP 3
It is mandatory to do the following:
1. Unplug the pump 4-pin PWM connector from the motherboard FAN
header (if already installed).
2. Plug the pump 4-pin PWM connector into the male 3-pin FAN con-
nector on enclosed EK-Cable Pump Testing Adapter (see picture un-
der STEP3 for explanation).
Your system is now ready to be charged for the fi rst time.
STEP 1
EK-ATx
Bridging Plug
Power supply ATx cable
STEP 3
Pump testing
adapter fan
header
Pump power
cable
STEP 2
Pump testing
adapter SATA
POWER header
Power supply
SATA cable