2 of 4
I
NSTALLATION
O
VERVIEW
1. Install the security system.
2. Run Cat5 wire from the
g!
system controller to the SuperBus Automation Module and test the
cable.
3. Test the security panel, zone sensors and keypads for proper functionality on their own.
4. Connect
the
g!
system to the panel electrically.
5. Configure
the
g!
communication device and security panel and confirm communication between
the panel and the
g!
system controller.
6. Test the arm/disarm capability from a computer or touch screen and confirm history function.
C
ONNECTION
D
IAGRAMS
1
2
5
3
GE Concorde 4 Panel
SuperBus 2000
Automation Module
DB9M to RJ45F Adapter
4
Cat5 Cable Assy.
g! System
Controller
25' Maximum length for
serial connection
4C 22AWG 1500' Max
(see panel installation manual for details)
RS232
B
ILL
O
F
M
ATERIALS
#
D e v ic e
M a nuf a c t ure r
P a rt N um be r
P ro t o c o l
C o nne c t o r T ype
N o t e s
1
Conco rd 4 Co ntrol P anel
GE
600-1040
Vario us
Screw Terminal
2
P rinter/Automation M o dule GE
60-783-02
RS-232
Screw Terminal x DB-9 Female
3
DB9M to RJ45 A dapter
ELA N
HA-CB-307
RS-232
DB-9 M ale X RJ-45 M ale
4
Cat5 Cable
Installer
N/A
RS-232
RJ-45 M ale X RJ-45 M ale
M ust terminate all 8 co nducto rs
5
g! System Contro ller
ELA N
Vario us (e.g. HC12)
RS-232
RJ-45
P
ANEL
P
ROGRAMMING
No special programming is required for the Concord. When the Automation Module is installed it is
automatically configured by the panel.