discount according to the mode the scale is in. It exits from any user input function. It is also used to reset the timer of
the hold function.
*
1/ UK Mainland/USA/Canada
It serves as t
he figure “1” and it selects Zone 1 (UK Mainland) for ParcelForce Express services or Zone 10
(USA/Canada destinations) for Global Value and Global Economy Parcels.
*
2/ Highlands/Islands of Scotland/Far East/Aus.
It serves as the figure “2” and it selects Zone 2 (Highlands and Islands of Scotland) for ParcelForce Express services or
Zone 11 (Far East/Australiasia) destinations for Global Value and Global Economy Parcels.
*
3/N. Ireland/Isles of Man/Isles of Scilly/Rest of World
It serves as the
figure “3” and it selects Zone 3 (Northern Ireland, Isles of Man, and Isles of Scilly) for ParcelForce
Express services or Zone 12 (Rest of the World destinations) for Global Value and Global Economy Parcels.
*
4/Channel Is.
It serves as the figure “4” and it selects Zone 4 (Channel Is. destination) for Global Value Parcels.
*
5/Rep. of Ireland
It serves as the figure “5” and it selects Zone 5 (Republic of Ireland destination) for Global Value Parcels.
*
6/Bel/Net/Lux
It serves as the figure “6” and it selects Zone 6 (Belgium, Netherlands, or Luxembourg destinations) for Global Value
Parcels.
*
7/Fra/Ger/Den
It serves as the figure “7” and it selects Zone 7 (France, Germany, or Denmark destinations) for Global Value Parcels.
*
8/Ita/Spa/Por
It serves as the figure “8” and it selects Zone 8 (Italy, Spain, or Portugal destinations) for Global Value Parcels.
*
9/Rest of Euro
It serves as the figure “9” and it selects Zone 9 (Rest of Europe destinations) for Global Value Parcels.
*
KEY BEEP
Press 0, 7, 9 to turn the key beeping on or off.
*
BACKLIGHT
Press 0, 7, 8 to turn the backlight on or off.
DISPLAY
*
OVERLOAD “OL”
This appears when the weight on the platform exceeds 5010 grams.
*
EXCESS WEIGHT “EE”
There are some postal services whose weight limit is less than the limit of the scale. EE appears to indicate that the
weight on the platform exceeds the weight allowed for that specific service.
ERROR DISPLAY
Err
will display if the scale is started without the platform or with items placed on the platform.
If the scale keeps displaying “Err” even if the scale has been started without anything on the platform, please follow these
instructions to fix the problem.
Turn off your scale and try putting the platform back to the scale or try removing the items placed on the scale’s platform.
Turn on your scale again. If this does not solve the
Err
display problem, you need to perform Auto Zero-Point calibration on
your Exceed UK scale. Please follow these steps:
1.
Remove any item placed on your scale’s platform and turn on your scale.
2. When
Err
is displayed on the LCD, press
HOLD
key on the keyboard. A cursor will blink on the scale’s LCD.
3. Press
0
key and then press
Enter
key on the keyboard.
4. At this point, the scale is adjusting its zero point value. Wait for the scale to finish this process. After this, it will
restart by itself. Exceed UK scale is now ready to use. If the scale continues to display
Err
, try to repeat the above
process for about three times.
Note: This Auto Zero-Point calibration is only available to Exceed UK with software version 5.1 or higher. If the Err problem
is not fixed by the above procedures, you need to update your scale with its latest software which can be found at:
http://www.elane.net/index.php?go=exceed_uk&category=exceed_scales
USER CALIBRATION
In case the scale was dropped or overloaded, user calibration might be required to ensure scale’s accuracy. User
calibration at 2kg is available. Please contact us for more details on how to do this.
CHANGES IN POSTAL RATES
The Exceed UK scale is equipped with a RS232 interface to let you connect it to your personal computer and
update the software easily whenever there is a postal rate or service change.
Any changes in postal rates, as well as in the services, can be easily implemented by purchasing the latest
software update for the scale. This contains the latest postal rates and/or new postal services. You also need to download
the Exceed PC Program which you can use to update your scale. This software is downloadable for free.
You can register your scale and get the latest application program for Exceed UK at:
http://www.elane.net/product_registration.php
.
Connecting the Scale to your PC
Connect the Exceed UK to your PC by using the RS232 cable that comes with the scale. You can use any available serial
port of your PC.