background image

 

   

7   

 

The UI allows the administrator to configure the management Vlan IP addresses. 

In case if the user has changed the management Vlan IP address, they need to assign 
the corresponding network address to his PC for the management access subsequently. 

Alternatively  the  user  can  access  the  device  via  the  static  IP  10.0.0.1  and 

configure the network settings during first time installation. Connect a PC to the LAN port 
of the STM and assign the IP address 10.0.0.100/255.255.255.0 to the PC. Now you can 
access the device from the browser using the URL 

https ://< 10.0.0.1> 

 

If the device is not accessible after configuring the new network configuration, Try 

rebooting the device and check the device dashboard accessing via Management Vlan.

 

 
On  launching  the  SIP  Firewall  WebUI,  the  web  application  will  prompt  to  enter  the 
administrator credentials to login. 
 

 

Figure 6: Login Page 

 
 
THE  FULL  VERSION  MANUAL  WILL  PROVIDE  YOU  DETAILED  INSTRUCTIONS 
ABOUT THE FULL FEATURE SET OF THE ELASTIX SIP FIREWALL 
 

Any Technical assistance required, Kindly contact the support at:

 

support@elastix.com

  

 

THANK YOU!

   

Summary of Contents for SIP Firewall

Page 1: ......

Page 2: ...Elastix SIP Firewall Quick Installation Guide ...

Page 3: ... 1 Table of Contents Overview 2 Deployment Considerations 3 Initial Setup Configuration 5 Accessing the WebUI 6 ...

Page 4: ...interface and 1 fast Ethernet WAN interface An additional USB port has been provided for adding the secondary USB storage that will be used by the appliance for archiving the security alert lock The factory reset button is located next to the USB Power socket Notification LEDs On the Front Panel of the SIP Firewall LED 4 Alert Status Power ON OFF LED 3 DPI Status Button LED 2 Interface Status Powe...

Page 5: ...nt Considerations The SIP Firewall has been made to protect the SIP based PBX Gateway Servers against SIP based network threats and anomalies Thus it is recommended to deploy the SIP Firewall along with the PBX Gateway deployment as given in the following scenarios based on what is applicable in the user s setup Scenario 1 Figure 3 Scenario 1 ...

Page 6: ...threats from the Public Cloud penetrated the Non SIP aware Corporate Firewall Figure 4 Scenario 2 Scenario 3 In the case of multiple IPPBX VOIP Gateways are deployed in the LAN Setup the following setup is recommended as it would help to protect against the threats from both Internal Network as well as the threats from the Public Cloud penetrated the Non SIP aware Corporate Firewall ...

Page 7: ...way 4 Connect the WAN port of the SIP Firewall to the untrusted public network 5 Connect the appliance to the power socket using the USB power cable 6 The device will take about a minute to boot up will be fully functional with the default configuration Some of the PBX Gateway devices may have an exclusive LAN Mgmt Interface for device management purpose other than the Data Interface also referred...

Page 8: ... management Vlan to access WebUI during initial setup The management Vlan configured on the device is accessible via the LAN WAN ports is made assigned to the default IP address 192 168 100 1 Use the procedure given below to access the WebUI 1 Connect the LAN port of the SIP Firewall to a PC 2 Assign the IP Address 192 168 100 2 to the PC Set the Net mask as 255 255 255 0 Now you can access the de...

Page 9: ...he IP address 10 0 0 100 255 255 255 0 to the PC Now you can access the device from the browser using the URL https 10 0 0 1 If the device is not accessible after configuring the new network configuration Try rebooting the device and check the device dashboard accessing via Management Vlan On launching the SIP Firewall WebUI the web application will prompt to enter the administrator credentials to...