background image

Elation Professional  -  www.elationlighting.com  - ELED Fresnel 100WW User Manual Page 5

Elation Professional  -  www.elationlighting.com  - ELED Fresnel 100WW User Manual Page 6

P

ower Supply:

 The ELED Fresnel 100WW™ contains an electronic 

ballast, which will auto sense the voltage when it is plugged into the 
power  source.  With  the  electronic  ballast  you  do  not  need  to  worry 
about wall voltage, this unit can be plugged in anywhere. Also be sure 
to only use the included I.E.C. power cable supplied with the unit.

DMX-512:

 DMX is short for Digital Multiplex. This is a universal pro-

tocol  used  as  a  form  of  communication  between  intelligent  fixtures 
and controllers. A DMX controller sends DMX data instructions from 
the controller to the fixture. DMX data is sent as serial data that trav-
els from fixture to fixture via the DATA “IN” and DATA “OUT” XLR ter-
minals located on all DMX fixtures (most controllers only have a DATA 
“OUT” terminal). 

DMX Linking: 

DMX is a language allowing all makes and models of 

different manufactures to be linked together and operate from a single 
controller, as long as all fixtures and the controller are DMX compliant. 
To  ensure  proper  DMX  data  transmission,  when  using  several  DMX 
fixtures try to use the shortest cable path possible. The order in which 
fixtures are connected in a DMX line does not influence the DMX ad-
dressing. For example; a fixture assigned a DMX address of 1 may be 
placed anywhere in a DMX line, at the beginning, at the end, or any-
where in the middle. When a fixture is assigned a DMX address of 1, 
the DMX controller knows to send DATA assigned to address 1 to that 
unit, no matter where it is located in the DMX chain.

Data Cable (DMX Cable) Requirements (For DMX Operation):

 

The  ELED  Fresnel  100WW™  can  be  controlled  via  DMX-512  proto-
col. The ELED Fresnel 100WW™ can be either a 1 or 2 channel DMX 
unit.  The  DMX  address  is  set  on  the  back  panel  of  the  ELED  Fresnel 
100WW™. Your unit and your DMX controller require a approved DMX-
512 110 Ohm Data cable for data input and data output (Figure 1). We 
recommend Accu-Cable DMX cables.  If  you  are 
making your own cables, be sure to use standard 
110-120 Ohm shielded cable (This cable may be 
purchased at almost all professional sound and 
lighting stores). Your cables should be made with 
a male and female XLR connector on either end 
of the cable. Also remember that DMX cable must 
be daisy chained and cannot be split.

Figure 1

Notice:

 Be sure to follow figures two and three when making your own 

cables. Do not use the ground lug on the XLR connector. Do not con-
nect the cable’s shield conductor to the ground lug or allow the shield 
conductor to come in contact with the XLR’s outer casing. Grounding 
the shield could cause a short circuit and erratic behavior.

DMX512 IN

3-PIN XLR

SOUND

REMOTE

CONTROL

INPUT

POWER

INPUT OUTPUT

SOUND

REMOTE

CONTROL

INPUT

POWER

INPUT OUTPUT

SOUND

REMOTE

CONTROL

INPUT

POWER

INPUT OUTPUT

DMX512

DMX+,DMX-,COMMON

1

2

3

Termination reduces signal errors and

avoids  signal  transmission  problems

and interference. It is always advisable

to connect a DMX terminal, (Resistance

120 Ohm 1/4 W) between PIN 2 (DMX-)

and PIN 3 (DMX +) of the last fixture.

1

2

3

1

2

3

DMX +

DMX -

COMMON

DMX512 OUT

3-PIN XLR

Figure 2

Figure 3

1 Ground

1 Ground

XLR Male Socket

XLR Pin Configuration

3 Hot

2 Cold

2 Cold

3 Hot

XLR Female Socket

Pin 3 = Data True (positive)

Pin 2 = Data Compliment (negative)

Pin 1 = Ground

Special Note: Line Termination.

 

When  longer  runs  of  cable  are 

used, you may need to use a terminator on the last unit to avoid erratic 
behavior. A terminator is a 110-120 ohm 1/4 watt resistor which is con-
nected between pins 2 and 3 of a male XLR connector (DATA + and 
DATA -). This unit is inserted in the female XLR connector of the last 
unit in your daisy chain to terminate the line. Using a cable terminator 
(ADJ  part  number  Z-DMX/T)  will  decrease  the  possibilities  of  erratic 
behavior. 

DMX512 IN

3-PIN XLR

SOUND

REMOTE

CONTROL

INPUT

POWER

INPUT OUTPUT

SOUND

REMOTE

CONTROL

INPUT

POWER

INPUT OUTPUT

SOUND

REMOTE

CONTROL

INPUT

POWER

INPUT OUTPUT

DMX512

DMX+,DMX-,COMMON

1

2

3

Termination reduces signal errors and

avoids  signal  transmission  problems

and interference. It is always advisable

to connect a DMX terminal, (Resistance

120 Ohm 1/4 W) between PIN 2 (DMX-)

and PIN 3 (DMX +) of the last fixture.

1

2

3

1

2

3

DMX +

DMX -

COMMON

DMX512 OUT

3-PIN XLR

Figure 4

5-Pin XLR DMX Connectors.

 

Some manufactures use 5-pin XLR 

connectors for DATA transmission in place of 3-pin. 5-pin XLR fixtures 
may be implemented in a 3-pin XLR DMX line. When inserting standard 
5-pin XLR connectors in to a 3-pin line a cable adaptor must be used, 
these adaptors are readily available at most electric stores. The chart 
below details a proper cable conversion.

Conductor

5-Pin XLR Male (In)

3-Pin XLR Female (Out)

Pin 1

Do Not Use

Do Not Use

Pin 3

Pin 2

Pin 1

Pin 3

Pin 2

Not Used

Not Used

Data True (+ signal)

Data Compliment (- signal)

Ground/Shield

3-Pin XLR to 5-Pin XLR Conversion

ELED Fresnel 100WW 

                                   DMX Set Up

ELED Fresnel 100WW 

                                   DMX Set Up

Summary of Contents for ELED FRESNEL 100WW

Page 1: ...ffordable intelligent fixtures The ELED Fresnel 100WW is a powerful DMX intelligent LED warm white spot The unit can be controlled manually or via DMX con troller Customer Support Elation provides a customer support line to provide set up help and to answer any question should you encounter problems during your set up or initial operation You may also visit us on the web at www elationlighting com...

Page 2: ...eat sources such as radiators heat registers stoves or other appliances inclu ding amplifiers that produce heat The fixture should be serviced by qualified service personnel when A The power supply cord or the plug has been damaged B Objects have fallen or liquid has been spilled into the appliance C The appliance has been exposed to rain or water D The appliance does not appear to operate normall...

Page 3: ...le and female XLR connector on either end of the cable Also remember that DMX cable must be daisy chained and cannot be split Figure 1 Notice Be sure to follow figures two and three when making your own cables Do not use the ground lug on the XLR connector Do not con nect the cable s shield conductor to the ground lug or allow the shield conductor to come in contact with the XLR s outer casing Gro...

Page 4: ...ions to any standard DMX controller Select your desired DMX mode and then press the UP or DOWN buttons to adjust the DMX address XXX DMX Address ELED Fresnel 100WW Operating Instructions Elation Professional www elationlighting com ELED Fresnel 100WW User Manual Page 8 Elation Professional www elationlighting com ELED Fresnel 100WW User Manual Page 7 3 To run the 1 Channel Mode press the MODE butt...

Page 5: ... down the outside casing 2 Clean the external optics with glass cleaner and a soft cloth every 20 days 3 Always be sure to dry all parts completely before plugging the unit back in Cleaning frequency depends on the environment in which the fixture operates i e smoke fog residue dust dew ELED Fresnel 100WW Trouble Shooting Listed below are a few common problems the user may encounter with solutions...

Page 6: ...rkmanship The sole responsibility of Elation Professionals under this warranty shall be limited to the repair of the product or replacement thereof including parts at the sole discretion of Elation Professionals All products covered by this warranty were manufactured after January 1 1990 and bear identifying marks to that effect E Elation Professionals reserves the right to make changes in design ...

Reviews: