EPAR QA Cleaning
Due to fog residue, smoke, and dust cleaning the internal and exter-
nal optical lenses must be carried out periodically to optimize light
output.
1. Use normal glass cleaner and a soft cloth to wipe down the
outside casing.
2. Clean the external optics with glass cleaner and a soft cloth
every 20 days.
3. Always be sure to dry all parts completely before plugging
the unit back in.
Cleaning frequency depends on the environment in which the fixture
operates (i.e. smoke, fog residue, dust, dew).
EPAR QA Trouble Shooting
Listed below are a few common problems the user may encounter,
with solutions.
Unit not responding to DMX:
1. Check that the DMX cables are connected properly and are
wired correctly (pin 3 is “hot”; on some other DMX devices
pin 2 may be ‘hot’). Also, check that all cables are connected
to the right connectors; it does matter which way the inputs
and outputs are connected.
Unit does not respond to sound:
1. Quiet or high pitched sounds will not activate the unit.
Elation Professional - www.elationlighting.com - EPAR QA Instruction Manual Page 18
Elation Professional - www.elationlighting.com - EPAR QA Instruction Manual Page 17
EPAR QA Photometric Chart
EPAR QA
Photometric Beam Angle Data
Standard 10° Beam Angle
LUX x 0.0929 = FC
R
G
B
A
ALL
267 FC / 2871 LUX
351 FC / 3774 LUX
42 FC / 450 LUX
165 FC / 1774 LUX
727 FC / 7830 LUX
64 FC / 691 LUX
94 FC / 1011 LUX
13 FC / 137 LUX
51 FC / 553 LUX
191 FC / 2060 LUX
33 FC / 350 LUX
40 FC / 428 LUX
6 FC / 62 LUX
24 FC / 259 LUX
91 FC / 981 LUX
10° Beam Angle
0 m
0 ft
1 m
3.28 ft
3 m
9.84 ft
2 m
6.56 ft
Ø 0.24 m / Ø 0.79 ft
Ø 0.48 m / Ø 1.57 ft
Ø 0.72 m / Ø 2.36 ft
Beam Diameter
10° Beam Angle
EPAR QA Dimmer Curve Diagram
Unit Dim Mode
(Fade Time)
(Fade Time)
Ramp Effect
Standard
Stage
TV
Architectural
Theatre
EPAR QA Power Consumption Setting
P001
62W
61W
P002
66W
66W
P003
77W
76W
EPAR QA
Display
120V/60Hz
230V/50Hz