Power Spot 700™
©Elation Professionals® Los Angeles, Ca. - wwww.ElationLighting.com - Page
29
minutes and attempt the lamp ignition process once again. After the 3rd
unsuccessful ignition attempt the sequence is completely stopped and
the display reads "
IG E
" (Ignition error).
LAER
After the ignition of the lamp was two times not successful the display
will show LAER. That means the lamp could be damaged or even
missed, the fixture is overheating or there could be a failure on the
igniter or ballast. Switch off the power supply and solve the possible
problem.
After the error "
IG E
" respectively "
LAER
" it is not anymore possible the start
the lamp via Shutter = 255. Nevertheless if a renewed ignition attempt is desired,
first run a Reset (at the Spot or over DMX). Afterwards you can try again to ignite
the lamp.
OTMP
This error message informs you that the fixture was overheating and
lamp has electronically been switched off to allow the fixture to cool to
normal operating temperatures. Please look for any possible reason
that may have caused the fixture to overheat. i.e., faulty fans, air vents
blocked or dirty, lamp broken or very old, too high ambient temperature.
Switch off the power supply and solve the possible problem.
RsER
This message informs you that one of the fixture function wasn’t able to
do its reset correct (magnetic sensor, stepping motor, driver on the
PCB, cables, etc.). Repair the defect and start the fixture again.
3. Operation
Operating Modes: The Power Spot 700™ can operate in three different modes. This next
section will detail the differences in the operating modes.
• Stand alone mode -
The fixture will react to sound, chasing through the built-in
programs.
• Master/Slave mode -
You can daisy chain up to 16 fixtures together to get a
synchronized light show without the need of an external controller. The fixtures will react to
sound chasing to synchronized light show.
• DMX control mode -
This function will allow you to control each individual fixtures traits
with a standard DMX-512 controller such as the Elation® Show Designer 2.
4.1 Universal DMX Control:
This function allows you to use a universal DMX-512
controller such as the Elation® DMX Operator II™ or Elation® Show Designer 2™ to