48
E R R O R C O D E S
When power is applied, the unit will automatically enter a
“Reset/Test”
mode. This mode brings all the
internal motors to a home position. If there is an internal problem with one or more of the motors an error
code will flash in the display in the form of
“XXer”
were as XX will represent a function number. For
example, when the display shows
“0Er”
it means there is some type of error with the Pan motor. If there
are multiple errors during the start-up process they will all flash in the display. For example: if the fixtures
has errors on
Channel 1
,
2
, and
5
all at the same time, you will see the error message
“01Er”,
“02Er”
,
and
”05Er”
flash repeated 5 times.
If an error does occur during the initial start-up procedure the fixture will self-generate a second reset
signal and try to realign all the motors and correct the errors. If the error persists after a second attempt
a third attempt will be made. If after a third attempt all the errors have not been corrected the fixture will
make the following determinations:
•
3 or More Errors -
The fixture cannot function properly with three or more errors therefore the
fixture will place itself in a stand-by mode until subsequent repairs can be made.
•
Less Than 3 Errors -
The fixture has less than 3 errors; therefore, most other functions will work
properly. The fixture will attempt to operate normally until the errors can be correct by a technician.
The errors in question will remain flashing in the display as a reminder of internal errors.
Error Codes are subject to change without any prior written notice.
ERROR CODES
DESCRIPTION
PAN Er
Movement is not located in the default position after the reset.
This message will appear after a fixture reset if the magnetic-
indexing circuit malfunctions (sensor failed, or magnet is missing)
or there is a motor failure (defective motor or a defective motor IC
drive on the main PCB). This error may also be displayed if the
head/yoke was blocked during a reset function.
TILT Er
Zoom Er
Movement is not located in the default position after the reset. This
message will appear after a fixture reset if the magnetic-indexing
circuit malfunctions (sensor failed, or magnet is missing) or there is
a motor failure (defective motor or a defective motor IC drive on
the main PCB).