Claw Strength Set up
VR1
–
Strength of initial claw grab in the down position (usually the highest voltage)
VR2
–
Strength once claw has the prize and is in motion towards prize chute (usually the lowest voltage)
VR3
–
Default 10% (every 10 plays the claw strength remains the same high voltage from initial grab to
drop off)
To set these properties you will need to have the machine powered off, and find the control panel,
pictured below.
1.
Press the Free Play button (located in the center of panel above) while cycling power on to the
machine.
2.
The Credit Display will flash. This indicates you are ready to change the settings.
3.
Using the joystick, scroll through the options by using the forward
▼ and back ▲ motions.
(Caution: when setting these voltages do not exceed 45V as this will lower the life of your solenoid coil
over time)
4.
Once all settings have been changed turn the game off to save current settings.
5.
Turn game back on and setting should be set.
Game Sequence and Behavior
Boot up
•
Music, RGB lights turn on
•
Claw
returns to home position, drops and pulls back up for self “switch test”