- 8 -
4000 4 332-EN-GE - 01/22
2 - PRELIMINARY INSTRUCTIONS
2-1
PACKAGING
The packing material of the power supply ALR3002M is intended to protect it during its transportation.
Keep it, it may be useful later one.
Packing list
1 instructions manual
1 plastic protecting bag
1 power supply : ALR3002M
2 cardboard packing piece
2-2 TECHNICAL FEATURES AT 230 V AND 23°C
2-2-1 AC voltages
Output voltage
: 6V, 12V and 24 V ± 3% (+15% max without load ) with common point
Outputs
: 4 mm diameter safety sockets
Output current
: 5 A
Protections
: Against short-circuits and overcurrent by incorporated thermal
circuit breaker (automatic rearmament after having deleted the
defect)
2-2-2 DC voltages
Output voltage
: 4 ranges 5 V, 6V, 12 V and 30 V adjustable from 0 V to V max.
Outputs
: 4 mm diameter safety sockets
Ripple
: 1 mV rms
Regulation for a load change from 0 to 100% : 10mV
Regulation for a line change from -6% to +7% : 5 mV
Internal resistance
: 4 m
Ω
Visualization
: Voltage regulation green LED
3 x 14 mm digits digital voltmeter
Voltmeter resolution
: 10 mV on 5 V and 6 V, 100 mV on 12 V and 30 V
Output current
: 3 ranges 25 mA, 250 mA and 2,5 A adjustable from 0 A to I max.
Regulation for a load change from 0 to 100% : 2 mA
Regulation for a line change from -6% to +7% : 1 mA
Visualization
: Current regulation red LED
3 x 14 mm digits digital ammeter
Ammeter resolution
: 100
μ
A on 25 mA, 1 mA on 250 mA, 10 mA on 2,5 A
OTHERS CHARACTERISTICS
Main input voltage
: 230 V ± 10 %, 50/60 Hz
Input voltage
: Cord with 2 poles
Consumption
: 200 VA
Dimensions
: L = 238 mm
H = 218 mm
D = 90 mm
Weight
: 4,2 Kg
Conditions of use
: +5°C to +40°C
Conditions of storage
: -10°C to +50°C
Conditions of moisture
: (see G.1)
Safety
: Class
II
reinforced safety between main input voltage and outputs.
EN 61010-1 standard - Overvoltage category II, pollution degree 2
EMC
: EN 61326-1
Electric strenght
: 2300 V between input and output and between input and chassis.
PROTECTIONS :
Safety class
:
II
Against short circuits
: by current regulation and thermal circuit breaker
Against overtemperature
: by controlled ventilation,
by power supplies shutdown,
by relay on the transformer,
by thermal circuit breaker incorporated on the transformer
Against overcurrent
: by internal 5x20 fuses (
F1
: F5A 250 V ,
F2
: T3.15A 250 V)
3- OVERALL VIEW
(see page 2)
3-1 CONTROLS DESCRIPTION
1
Main switch
2
AC outputs
3
DC voltage display
4
DC current display
G.1
8 0
5 0
3 1
4 0
° C
%
m
a x i m
u m
r e l a t i v e
m
o i s t u r e
ENGLISH