Command & Answers
Description
Answer :
[Address] OK
Command :
[Address] OCP WR [0-6100]
Answer :
[Address] OK
Writing the limit current setpoint (mA) channel 1,
In double mode.
Writing the limit current setpoint (mA) in serial, parallel
or tracking mode.
Command :
[Address] OUT WR [0-1]
Answer :
[Address] OK
Disconnect / Connect the output.
Command :
[Address] RCL WR [1-16]
Answer :
[Address] OK
Recall the configuration memorised.
Command :
[Address] STO WR [1-16]
Answer :
[Address] OK
Save the usual configuration.
Command :
[Address] REM WR [0-1]
Answer :
[Address] OK
Mode
‘Local’ => 0.
Mode ‘Remote =>1
Command :
[Address] VOLT RD
Answer :
[Address] OK [0-32200]
Reading the voltage setpoint in mV.
Command :
[Address] CURR RD
Answer :
[Address] OK [0-6100]
Reading the current setpoint in mA.
Command :
[Address] OVP RD
Answer :
[Address] OK [0-32100]
Reading the limit voltage setpoint in mV.