4000 4 362-03-21
21
ENGLISH
Command & Answers
Description
Command :
[Address] OCP RD
Answer :
[Address] OK [0-6100]
Reading the limit current setpoint in en mA.
Command :
[Address] OUT RD
Answer :
[Address] OK [0-1]
Reading the output connection.
Command :
[Address] REM RD
Answer :
[Address] OK [0-1]
0 => Mode ‘Local’.
1 => Mode ‘Remote
Command :
[Address] MODE RD
Answer :
[Address] OK [0-2]
0 => not defined mode (output OFF)
1 => voltage regulation mode.
2 => current régulation mode
Command :
[Address] VOLT MES
Answer :
[Address] OK [0-32200]
Measure the output voltage in mV.
Command :
[Address] CURR MES
Answer :
[Address] OK [0-6100]
Measure the output current in mA.
Command :
[Address] SERIAL RD
Answer :
[Address] OK [0-N]
Read the serial number of the device.
Command :
[Address] IDN RD
Answer :
[Address] OK ALR3203 VERSION [N]
Read the device ID.