4000 4 362-03-21
6
ENGLISH
3.1.1 Connections
O and -
Front panel
Safety terminals Ø4 mm
Ground terminal
Front panel
Safety terminals Ø4 mm
3.1.2 Display
Display
LCD graphic display FSTN N&B 3.2 inch
Resolution
128 x 64 pixels
Backlight
White LED
3.1.3 Protections
Against short-circuits
By current regulation
Against over-temperature
By thermal circuit-braker
Against over-current on main source
By internal fuse (T1.6A ; 250V ; 5x20)
3.1.4 Memories
Memory
Storage
15 configurations
Recall
15 + 1(factory configuration)
3.1.5 Functions
Functions accessible by keypad
7 available
In Voltage or Current
SQUARE periodic
RAMP positive and negative
periodic and single shot
ARBITRARY periodic and
multi shot
Timer (2 Ranges)
Seconde or minute
100 ms to 50 min
3.1.6 Standby
Isolation mode of the output
Enable / disable output
Standby mode
Puts the power supply in standby mode
3.1.7 Interfaces
Isolation / output
150 Vdc
Isolation / Earth
150 Vdc
USB
Serie
Processing time of control
< 20ms
3.1.8 Other caracteristics
Power source
220
–
240 Volts ±10%, 50
–
60 Hz
EEC socket C14 for cable 2 poles + earth C13 (2P + E)
Maximum power consumption
126W (<4W in Standby mode)
Internal fuses (x2) AC input
5 x 20 ; 250V T1.6A
Efficiency
> 78% of the maxi powerful
Safety
Class I, CAT II, degree of pollution 2
Complies with EN 61010-1, CAT II
CEM
Complies with EN 61326-1 & EN 55011
Voltage on the earth
± 150 Vdc