background image

 

Using memories 
 
The focus HAND3 has 51 memories on board. 
 
Recording a memory 
 
Create the scene as normal. 
 
Next press: 
[Func] [- / Store] number of the memory [Enter] 
 
Recalling a memory 
 
Press: 
[Func] [+ / memory] number of the memory [Enter] 
 
Using Startup memory 
 
If memory 0 is programmed then the unit will automatically activate in merge mode at power on. 
Memory 0 can be programmed with channels at certain levels or with all channels at 0%. To erase 
memory 0, store memory 0 with all 512 channels at FULL (best to disconnect the DMX output before 
setting all channels at FULL). 
 
Using multiple remotes at the same location 
 
To use multiple remotes in the same location, without interfering, you’ll need to make change some 
settings in both remote and base unit. 3 possible settings are possible called: ‘0’ (factory default) ‘+’ 
and ‘-‘. 
 
Changing the base unit’s encoding  

(this may only be done by qualified personnel, because you’ll need to open the cabinet)

 

 

 

Unplug the main power supply 

 

Open the cabinet (6 screws) 

 

Find the location of the settings, it is a jumper array marked by 0 + -  (at the front) 

 

Set the jumper to the correct setting 

 

Close the cabinet 

 
Changing the remote’s encoding 

(this can be done at any time, even to use 1 remote for up to 3 locations) 

 

Switch off the remote (slide switch) 

 

Press and hold the ‘0’ ‘+’ or ‘-‘ key 

 

Switch on the remote (slide switch) 

 

Wait for a few seconds (keeping the key pressed) until the leds start flashing.  

 
Troubleshooting 
 
If for some reason you can’t get any connection between the HF remote and the base unit. Please first 
check the batteries of the remote. If they are ok then the remote might have accidentally been set to a 
different encoding. Follow the procedure described above. 

 
General Information 

 
CE – Product 
The Focus Hand System permits to the CE requirements set-up by the European Community. This 
can be recognized by this label on the outside of the product. 
 
 
 
 

 

Summary of Contents for focus HAND 3

Page 1: ...focus HAND 3 512 channel wireless DMX riggers remote Users Manual Software version 1 0 ...

Page 2: ...s them into the proper DMX values The receiver unit has to be connected between the lighting consoles DMX output and the dimmers DMX input where it will take over the control of the DMX line This can be activated with the remote unit so the receiver can be permanently connected Not only one spot at a time can be controlled but also groups and level can be adjusted from off to 100 Even groups and m...

Page 3: ...m replace it with a fresh one and close the lid with the same M3x4mm screws Be sure not to throw the old battery in the normal dustbin but remove it adequately Using alkaline batteries is recommended Keypad layout Key illumination The keys on the transmitter are illuminated While a key is pressed the unit is transmitting indicated by bright illumination of the keys When releasing the key the illum...

Page 4: ...he lighting desk Receive A valid signal is received from the remote Operation Activation with HTP merge Type in the code ENTER This action activates the receiver unit taking over the DMX control The DMX output will be an Highest take Precedence merge of the DMX input and the channels generated by the remote Activation without HTP merge Type in the code 0 ENTER This action activates the receiver un...

Page 5: ... ENTER removes dimmer 3 from selection 3 THRU 8 removes dimmers 3 to 8 Clear Stage remove all To clear the selection press 0 ENTER Stepping thru dimmers Press FUNC then you can use NEXT PREV UP and DOWN for stepping thru the dimmer channels and adjusting the total level When finished press ENTER Toggle between presets Press ENTER for switching between the current and previous setting Using groups ...

Page 6: ...coding this may only be done by qualified personnel because you ll need to open the cabinet Unplug the main power supply Open the cabinet 6 screws Find the location of the settings it is a jumper array marked by 0 at the front Set the jumper to the correct setting Close the cabinet Changing the remote s encoding this can be done at any time even to use 1 remote for up to 3 locations Switch off the...

Page 7: ...mpliance with FCC regulation shielded cables must be used with this equipment Operation with non approved equipment or unshielded cables is likely to result in interference to radio television reception CAUTION Changes or modifications not expressly approved by ELC lighting and Leprecon LLC may void the users authority to operate this equipment R TTE regulations 433 92MHz EU version The HF modules...