background image

ELCART

ELCART DISTRIBUTION SPA  via Michelangelo Buonarroti, 46 - 20093 Cologno Monzese (Milano) ITALY

Tel. +39 02.25117310 Fax +39 02.25117610 sito internet:  www.elcart.com    e-mail: info@elcart.it

Manuale di istruzioni/Scheda tecnica

La divulgazione dei dati contenuti in questa scheda è da ritenersi un servizio puramente informativo e non costituisce alcun vincolo da parte della Elcart in merito a prestazioni ed utilizzo del prodotto.

The divulgation of data contained on this technical sheet are exclusively for informational reasons and establish no link on behalf of Elcart regard to thr performances and the usa of the product.

La divulgacion de los datos contenidos en esta ficha son un servicio unicamente informativo y no constituyen ningun vinculo de parte de Elcart respecto a las prestaciones y uso del producto.

ART. 9/9450

PAGINA 6 DI 9

1.1.3 Symbols:

 

Caution: refer to the instruction manual. 

 

Incorrect use may result in damage to the device 

 

or its components

 

AC (Alternating Current) 

DC (Direct Current)

 

Earth ground 

Double insulated

 

Fuse 

Conforms to European  

 

 

Union directives

1.1.4 Instructions

*  Remove test leads from the Meter before opening the battery cover.

*  When servicing the Meter, use only specified replacement parts.

*  Before opening up the instrument, always disconnect from all sources of  

  electric current and make sure you are not charged with static electricity

*  Any adjustment, maintenance or repair work carried out on the meter while  

  it is live should be carried out only by appropriately qualified personnel,    

  after having taken into account the instructions in this present manual. 

*  A "qualified person" is someone who is familiar with the installation,  

  construction and operation of the equipment and the hazards involved.  

  He is trained and authorized to energize and de-energize circuits and  

  equipment in accordance with established practices.

* When the instrument is opened up, remember that some internal  

 

  capacitors can retain a dangerous potential even after the instrument  

  is switched off.

*  If any faults or abnormalities are observed, take the instrument out of  

  service and ensure that it cannot be used until it has been checked out.

*  If the meter is not going to be used for a long time, take out the battery and  

  do not store the meter in high temperature or high humidity environment.

1.2 Protection mechanisms 

*  Fused by the fuse (FF400mA/1000V) during capacitance,temperature,  

  mA and hFE measurements.

*  A PTC resistor protects against permanent over-voltages of up to 250V  

  during resistance, frequency, continuity and diode test measurements.

2. DESCRIPTION

2.1 Instrument Familiarization

  

1. Voltage alert area 

  

 

 

2. Voltage alert light 

 

  

 

 

3. LCD display  

  

 

 

4. Keypad 

 

  

 

 

5. Rotary switch  

  

 

 

6. Terminals

2.2 Display LCD

 

SYMBOL

MEANING

The battery is low

Warning:

To avoid false readings and malfunction, replace the 

battery as soon as the battery indicator appears.

-

Indicates negative readings

Indicator for ac voltage or current. 

AC voltage and current are displayed as the average of 

the absolute value of the input, calibrated to indicate the 

equivalent rms value of a sine wave.

DC

Indicator for dc voltage or current

The Meter is in the Diode Test mode

The Meter is in the Continuity Check mode

The Meter is in the Data Hold mode

mH / H

H: Henry, the unit of inductance

mH: Milli Henry 1x10

-3

 or 0.001 henry

V,mV

V: Volts, the unit of voltage

mV: milliVolts 1x10

-3

 or 0.001 volts

A,mA,µA

A: Amperes (amps), the unit of current

mA: Milliampere 1x10

-3

 or 0.001 amperes

µA: Microampere 1x10

-6

 or 0.000001 amperes 

Ω,KΩ,MΩ

Ω: Ohm, the unit of resistance

KΩ: Kilo ohm 1x10

3

 or 1000 ohms

MΩ: Mega ohm 1x10

6

 or 1.000.000 ohms

KHz

KHz: Kilohertz 1x10

or 1000 hertz

 

F,µF,nF

F: Farad, the unit of capacitance

µF: Micro Farad 1x10

-6

 or 0.000001 farad

nF: Nano Farad 1x10

-9

 or 0.000000001 farad

2.3 Keypad

KEY

OPERATION PERFORMED

turn the meter ON or OFF

HOLD

Press HOLD to enter and exit the Data Hold mode

Press to turn the backlight on. 

After about 5 seconds, the backlight is auto-off. 

2.4 Terminals

TERMINAL

DESCRIPTION

COM

Return terminal for all measurements. 

(Receiving the black test lead or the “COM” plug)

      V/Ω

Input for voltage, resistance, diode 

and continuity measurements

     hFE/mA/Lx

Input for capacitance, Inductance, hFE and mA 

current measurements

10A

Input for 200mA to 10A current measurements

2.5 Accessories

Delivered with the multimeter:
* User's manual
* Test leads
* Carry case

Special Multi-function socket

~

AC

~

H

Summary of Contents for 9/9420

Page 1: ...isurazioni effettuate nel l ambito domestico La categoria di misurazione II relativa alle misurazioni effettuate su circuiti collegati direttamente a una bassa tensione La categoria di misurazione I r...

Page 2: ...isplay 4 Pulsanti 5 Manopola 6 Terminali 2 2 Display LCD SIMBOLO SIGNIFICATO La batteria scarica Per evitari guasti e malfunzionamenti sostituite la batteria Indicatore letture negative Indicatore per...

Page 3: ...000m Temperatura di utilizzo 0 C 40 C 32 F 122 F 80 RH 10 C senza condensa Temperatura di conservazione 10 C 60 C 14 F 140 F 70 RH rimuovere la batteria Coefficiente di temperatura 0 1 precisione spec...

Page 4: ...NZIONE Non tentate di riparare lo strumento Solo persone qualificate possono effettuare riparazioni tecniche sul multimetro 5 1 Manutenzione generale ATTENZIONE Per evitare danneggiamenti non utilizza...

Page 5: ...easurement category I is for measurements performed on circuits not directly connected to MAINS When using this Multimeter the user must observe all normal safety rules concerning protection against t...

Page 6: ...e and ensure that it cannot be used until it has been checked out If the meter is not going to be used for a long time take out the battery and do not store the meter in high temperature or high humid...

Page 7: ...ircuit being measured and read the displayed value NOTE On 20M and 200M ranges the meter may take a few seconds to stabilize reading this is normal for high resistance measuring 3 2 3 Diode Test WARNI...

Page 8: ...ds and recover the measured circuit 4 TECHNICAL SPECIFICATIONS 4 1 GENERAL SPECIFICATIONS Environment conditions 1000V CAT II e 600V CAT III Pollution degree 2 Operating altitude 2000m Operating tempe...

Page 9: ...not attempt to repair or service your Meter unless you are qualified to do so and have the relevant calibration performance test and service information 5 1 General Maintenance WARNING To avoid electr...