PAGINA 9 DI 9
4.2.6 Transistor
RANGE
DESCRIPTION
TEST CONDITION
hFE
Display read approx. HFE value
(0-1000) of transistor under test
(all type)
Base Current approx.
10μA, Vce approx. 2.8V
4.2.7 Inductance
RANGE
RISOLUZIONE
PRECISIONE
20mH
0.01mH
±(3.0% of rdg+5digits)
200mH
0.1mH
±(3.0% of rdg+5digits)
2H
1mH
±(3.0% of rdg+5digits)
20H
10mH
±(3.0% of rdg+5digits)
Overload protection:
fuse (FF400mA/1000V)
4.2.8 Capacitance
RANGE
RESOLUTION
ACCURACY
20nF
10pF
±(4.0% of rdg+3digits)
200nF
0.1nF
±(4.0% of rdg+3digits)
2µF
1nF
±(4.0% of rdg+3digits)
200µF
100nF
±(5.0% of rdg+10digits)
Overload protection:
fuse (FF400mA/1000V)
4.2.9 DC Current
RANGE
RESOLUTION
ACCURACY
200mA
0.1mA
±(1.5% of rdg+1digits)
10A
10mA
±(2.0% of rdg+5digits)
Overload protection:
fuse (FF400mA/1000V)
10A range fuse(FF10A/500V)
Max. input current:
200mA dc or 200mA ac rms for mA range
10A dc or 10A ac rms for 10A ranges
For measurements>5A:
10 Seconds maximum ON to measure 1 minutes OFF
Above 10A unspecified
4.2.10 AC Current
RANGE
RESOLUTION
ACCURACY
200mA
0.1mA
±(1.8% of rdg+3digits)
10A
10mA
±(3.0% of rdg+7digits)
Overload protection:
Resettable fuse (FF400mA/1000V)
10A range fuse(FF10A/500V)
Max. input current:
200mA dc or 200mA ac rms for mA range
10A dc or 10A ac rms for 10A ranges
For measurements>5A:
10 Seconds maximum ON to measure 1 minutes OFF
Above 10A unspecified
Frequency Range:
40Hz-400Hz
Response:
Average, calibrated in rms of sine wave
5. MAINTENANCE
Do not attempt to repair or service your Meter unless you are qualified
to do so and have the relevant calibration, performance test, and service
information.
5.1 General Maintenance
WARNING
To avoid electrical shock or damage to the meter,
do not get water inside the case.
Remove the test leads and any input signals before
opening the case
Periodically wipe the case with a damp cloth and mild detergent.
Do not use abrasives or solvents.
Dirt or moisture in the terminals can affect readings.
To clean the terminals:
- Turn the meter off and remove all test leads.
- Shake out any dirt that may be in the terminals.
- Soak a new swab with a cleaning and oiling agent (such as WD-40).
- Work the swab around in each terminal. The oiling agent insulates the
terminals from moisture-related contamination.
5.2 Battery and Fuse replacement
WARNING
To avoid false readings, which could lead to possible electric
shock or personal injury, replace the battery as soon
as the battery indicator ( ) appears.
Use only fuses with the amperage,interrutp,voltage
And speed ratings specified
FF400mA/1000V Min interrupt rating 10000A
FF10A/500V Min interrupt rating 10000A
To replace the battery of fuse:
- Turn the meter off.
- Disconnect test leads and/or any connectors from the terminals.
- Use a screwdriver to unscrew the two screws secured on the battery
cover.
- Take out the battery cover from the meter.
- Remove the used batteries or damaged fuse.
- Replace with the new 9V batteries (6F22) or new fuse.
- Rejoin the battery cover and secure by the two screws.
IMPORTED AND DISTRIBUTED BY:
ELCART DISTRIBUTION SPA
Via Michelangelo Buonarroti, 46
20093 COLOGNO MONZESE (MI)
ITALY
www.elcart.com - info@elcart.it
Information for users:
The symbol on the equipment indicates that the waste must be “separately collected”.
Therefore, the user must carry (or have it carried) the waste to the separately collected
waste centers set up by local governments, or deliver it to the dealer against purchase
of a new equivalent-type equipment.
The separate waste collection and the subsequent processing, recovery and disposal
operations favour the production of equipment with recycled materials and limit the
negative effects on the environment and on health which may be possibly caused by
the waste improper management.
The improper product disposal by the user causes the application of administrative
sanctions according to the Art. 50 et. seq. of the Law Decree No. 22/1997.
Made in China