21
User level
Timer settings
The controller has a total of 45 timer
settings that can be distributed at will
over 7 channels or can be assigned to
specific functions.
Press the following keys in sequence
to assign switching times for the va-
rious timer channels
displays the first active timer channel
Select the first on time setting (I) by pressing the plus or minus key.
Set the hour.
Set the minute.
Set the day
(each day individually or Monday to Sunday).
Use the plus key to set the off time (0).
Continue setting hours, minutes and days as described above.
If you have finished entering timer set-
tings, press the question mark key until
the channel number (e.g., CH1) and
END appear in the display.
The other programmed timer channels
appear next. To skip a timer channel
(because no settings are required),
press the question mark key, then
press the enter key twice. The next
available timer channel appears in the
display. You may now enter the timer
settings as described above.
Channel CH1 (NHZ)
backup heating times
Channel CH2 (ANTI)
anti-Legionella enable
Channel CH3 (WWU)
hot water destratification
Channel CH4 (TH1)
first thermostat function
Channel CH5 (TH2)
second thermostat function
Channel CH6 (VER1)
first differential temperature function
Channel CH7 (VER2)
(CW)
second differential temperature function or collector
monitoring function if CW = 1 (E3-3.6)