30
Servicing instructions
Fan impeller
Note:
Prior to removing the fan impeller, the
shaft or the fan impeller must be mar-
ked on the edge of the suction funnel so
that the fan impeller is in the same posi-
tion when reassembling, or the same
overlapping of the suction funnel
(dimension in Fig.) can be readjusted
as initially. An axial displacement of the
impeller on the shaft may result in a
lower efficiency, thus having a reduced
air flow.
Prior to removing the bush from the
disk, the position of the bush in the disk
must be marked so that a rotating
against one another can be prevented.
Rotating the bush deteriorates the
balance of the fan impeller.
To demount the impeller, remove the
screws (1) and (2), screw in one of
them as separating screw into the hole
(3) having half a thread in the bush and
tighten it.
This causes the bush to loosen. Open
the bush by means of a wedge if requi-
red. Remove the loose impeller ran wit-
hout striking a blow and without
damage by hand.
- Clean and degrease all bright-finished
surfaces. A requirement for achieving
a high slipping moment is always a
clean and fat free
surface of all parts
to be fitted into one another.
- For reassembly: Place the disk and
the bush into their initial position (wit-
hout rotating) into one another, make
sure that the holes are congruent.
- Screw the bush into or out from the
disk until about 2..3 mm of the bush
are protruding.
- For new installation: Mark the dimen-
sion x on the inside of the fan impeller.
- Mount the fan impeller onto the shaft.
For this, open the bush by means of a
wedge if required. Adjust the position
to maintain the dimension x using the
marking(s).
- Align the two opposing screws (1) and
(2) and tighten them evenly step by
step. In doing so, start with the first
step of the torque (max. 10 Nm) by
tightening one screw, then rotate the
fan impeller by half a rotation and tigh-
ten the other screw with the same tor-
que, afterwards rotate the fan impeller
to the initial position. Increase the tor-
que by one step and proceed until the
specified torque is reached as descri-
bed above. The torque steps should
not be larger than 10 Nm.
- check the dimension X.
The following torques must be
followed:
SM 25, Bushes No. 2517 – centre bore
42 and 48 mm:
Torque: 50 Nm.
WM30 Bushes No.3030 – centre bore
48 mm:
Torque: 90 Nm.
Overlapping of suction funnel above
fan impeller: 6 mm
x=6 mm
12/2011 14 072 205
Summary of Contents for Low-NOx N10.12000.30 G-EU2