18
09/2005 - Art. Nr. 13 019 526A
Start-up
Default settings
Burner power
Dimension
Y
mm
Air flap opening
Gas throttle opening
Pressure
adjustment
setting
pVA mbar
Low load
kW
Rated load
kW
Ignition
load
P0 (°)
Low load
P1 (°)
Rated load
P9 (°)
Ignition
load
P0 (°)
Low load
P1 (°)
Rated load
P9 (°)
140
400
10
0
0
25
23
23
39
15
150
500
20
0
0
29
23
23
43
15
160
600
35
5
5
40
24
24
50
15
170
700
40
5
5
45
24.5
24.5
62
15
Natural gas settings table G 05.700 MODULO
Natural gas settings table G 05.1000 MODULO
Burner power
Dimension
Y
mm
Air flap opening
Gas throttle opening
Pressure
adjustment
setting
pVA mbar
Low load
kW
Rated load
kW
Ignition
load
P0 (°)
Low load
P1 (°)
Rated load
P9 (°)
Ignition
load
P0 (°)
Low load
P1 (°)
Rated load
P9 (°)
170
600
20
0
0
38
26.5
26.5
56
15
170
700
25
2
2
41
26.5
26.5
65
15
200
800
30
6
6
68
27
27
90
18.5
220
900
35
8
8
68
28
28
90
18.5
250
1000
40
9
9
68
29
2
90
18.5
Propane gas settings table G 05.700 MODULO
Propane gas settings table G 05.1000 MODULO
Burner power
Dimension
Y
mm
Air flap opening
Gas throttle opening
Pressure
regulator
setting
pVA mbar
Low load
kW
Rated load
kW
Ignition
load
P0 (°)
Low load
P1 (°)
Rated load
P9 (°)
Ignition
load
P0 (°)
Low load
P1 (°)
Rated load
P9 (°)
140
400
10
4
4
20
19
19
30.5
15
150
500
20
4
4
29
19
19
36
15
160
600
30
4
4
36
19
19
41
15
170
700
40
4
4
40
19
19
45
15
Burner power
Dimension Y
mm
Air flap opening
Gas throttle opening
Pressure
regulator
setting
pVA mbar
Low load
kW
Rated load
kW
Ignition
load
P0 (°)
Low load
P1 (°)
Rated load
P9 (°)
Ignition
load
P0 (°)
Low load
P1 (°)
Rated load
P9 (°)
170
600
15
6
6
36
19.5
19.5
42
17.5
170
700
20
6
6
63
19.5
19.5
75
17.5
200
800
25
7
7
63
19.5
19.5
75
17.5
220
900
35
7
7
68
19.5
19.5
75
17.5
250
1000
40
8
8
68
22
22
75
17.5
The above setting data are
basic settings.
The factory setting data are in boxes with thick black borders. The burner can
normally be run using these settings. Check the setting values carefully in each case. System-specific corrections may be
necessary.