68
earth connection with a brass seal under which the temperature sensor (Minimum-
Maximum operating temperatures) can be found.
5.
On the left side >>at 9 O’clock<< there is the reversible thermostat. In the middle,
between the two electrical connections, the reverse push button can be seen (beige-
brown). This push button must be in the pushed-in position.
Wait and see what happens! If the thermostat is working correctly, go directly to
point 8 of this section (changing the circuit board).
6.
After the reverse push button has been set in the pushed-in position, close the
machine for testing (do not reassemble the top front cover!). Switch the machine on
following operating instructions. Wait until the top left and top right leds (showing
brewing water and hot water/steam temperature) remain alight. For testing
purposes, turn the knob on the front panel and check whether hot water is delivered
from the wand. In the event that the thermostat should cut out again, then the fault
could be with the sensor on the relative heat exchanger. In this case, disconnect
power supply to machine and open it up.
7.
Follow the special instruction for changing the sensor. Contact your servicing firm.
8.
Now find a >>clear working space<< as the diagnostics and settings panel needs to be
disassembled.
On the left, the top
thermostat. Centre,
the reverse push
button.
The sensor is
under this
earth
connection
Summary of Contents for SUPREME DED400XP1
Page 1: ...EXPRESSO DED400XP1 ...