51
Programming manual
First Euro phase – the start of dual display
Dual display is used to print an informational currency conversion for the future currency at the bottom of
each receipt. The dual displayed currency conversion has only an informational character and is not used
for any other purpose. Each sale price will be converted to the new currency using the official conversion
rate. The electronic cash register allows for the starting and stopping of dual display during any phase of
the Euro changeover.
Procedure for initiating dual display:
1) Switch into programming mode by pressing the key combination
.
2) Enter the code
.
3) Enter the conversion rate, such as: “1EUR = xx.xxxx SEK“ and set this value using the key
.
4) Confirm the setting of the conversion rate by pressing the
, key. After a successful setting, an infor-
mational receipt will be printed out:
Växlingskurs
1EUR=10.4735 SEK
Dubbel visning
av
5) Enter the code
to start dual display.
An informational receipt will be printed out:
Växlingskurs
1EUR=10.4735 SEK
Dubbel visning
pa.
Note:
By entering the code
again, dual display will be stopped/started.
Warning:
A correctly entered conversion rate is the responsibility of the authorized electronic cash register opera-
tor and therefore be sure to check the correctness of the conversion rate.
Second Euro phase – dual currency circulation
Upon changing to the second euro phase, the GT1, GT2 and GT3 will be automatically converted to the
conversion rate of the new currency.
Upon entering this mode, dual display starts automatically, if it was not started in the past. During this phase,
the electronic cash register operates with two currencies. The main currency will be the new currency (EUR)
and the secondary currency will be the previous main currency (SEK).
The parameter of first system flag is set automatically to 002222 (a description of the first system flag is in
figure 3.1). The first flag respects the legal requirements, and it’s suggested to leave this default value or to
change it only after consulting with an expert advisor.
Procedure for the start of dual display:
1) Switch into Z mode by pressing the key combination
.
2) Execute all reports from Z mode (see the chapter describing reports).
3) Execute all reports from Z mode (see the chapter describing reports)
.
4) Enter the code
.
5) Confirm the setting by pressing the
key.
6) Conversion of prices in the cash register PLU and DPT database from SEK to EUR.
During the currency changeover, prices from the electronic cash register database (PLU and DPT) are not con-
verted to the new currency – EUR. This can be done manually or with help of the communication software.
Summary of Contents for Euro-200TE
Page 1: ...Euro 200TE User manual Swedish version 1 1...
Page 8: ......
Page 9: ...INTRODUCTION...
Page 15: ...CASH REGISTER CHARACTERISTICS...
Page 27: ...PROGRAMMING MANUAL...
Page 58: ......
Page 59: ...OPERATION IN REGISTRATION MODE...
Page 85: ...REPORTS...
Page 100: ......
Page 101: ...EURO2A SOFTWARE...
Page 103: ...OPTIONAL ECR ACCESSORIES...
Page 107: ...HELPFUL ADVICE...
Page 114: ...114 Note...