4.16 Scanner and scales connection to the Euro-500TX Handy via the RS-232
interface
The scanner and scales are connected to the ECR Euro-500TX Handy using the 6-pin Modular jack con-
nector on the rear ECR panel.
RS-232 communication settings for the scanner and the scales have to be set the same as on the ECR.
5
4
3
2
1
9
8
7
6
5
4
3
2
1
9
8
7
6
6 5 4 3 2 1
6 5 4 3 2 1
Modular jack 6×6 Euro-500TX Handy
Top view
Front view
D-SUB 9 M - Scanner
D-SUB 9 M - Scales
Rear view
(from the soldering loops)
Signal
D-SUB 9 M (Scanner)
RxD
2
GND
5
VCC
9
Signal D-SUB 9 M (Scales)
RxD
2
TxD
3
GND
5
Fig. 4.25 Scanner/scales communication cable connexion
Tab. 4.13 Pin connexion for the scanner