background image

Dry Film Thickness -  

Dry Film Thickness is probably the most critical measurement in the coatings industry. It provides 
vital 

information as to the expected life of the substrate, the product’s fitness for purpose, its 

appearance and ensures compliance with a host of International Standards. 

 

• Integral and Separate gauges available 
• Ferrous, Non-Ferrous, Ferrous – Non-Ferrous dual gauges available  
• Dust and water resistant rugged design equivalent to IP64 
• Fast reading rate of more than 70 readings per minute 
• USB and Bluetooth® data output to ElcoMaster™ 2.0 software suite of products 
• Calibration Test Certificate comes with Gauges 

Elcometer 456  

Digital DFT Gauge

 

Integral Model Options ( Built in Probe ) 

 

 

Scale 1

 

 

Range: 

0-

1500μm

 (0-60mils) Accuracy*: ±1-3% or ±

2.5μm (±0.1mil) 

 
 

 

 

Model E  

  Model B  

  Model S  

  Model T  

Elcometer 456 Ferrous Integral    

A456CFEI1  

A456CFBI1 

 A456CFSI1  

A456CFTI1 

  

Elcometer 456 Non-Ferrous Integral  

     

N/A 

A456CNBI1 

 

See separate gauges  with 

N2 PINIP™ Probe 

 

 
Elcometer 456 Dual FNF Integral  

A456CFNFEI1   A456CFNFBI1   A456CFNFSI1  A456CFNFTI1 

  

 
 

Scale 2 

 

Range: 

0-5mm

 (0-200mils) Accuracy*: ±1-3% or ±

20μm (±1.0mil) 

 

For higher  resolution  & accuracy on thin coatings  Scale  2 gauges  can be switched  to the Scale  1 mode measurement  performance 

 
 

 

 

Model E 

   Model B               Model S            Model T 

Elcometer 456 Ferrous Integral    

       

-  

 A456CFBI2 

    

See separate gauges  with F2 PINIP™ Probe 

 

 

 
 

Scale 3

 

 

Range: 

0-13mm

 (0-500mils) Accuracy*: ±1-3% or ±50

μm (±2.0mils) 

 
 

 

 

Model E 

 

    

Model B 

 

        

Model S 

         

Model T 

Elcometer 456 Ferrous Integral   

 

  

A456CFBI3

 

    

See separate gauges  with F3 

PINIP™ Probe 

 

Summary of Contents for E224C-BI

Page 1: ...ian Distributor elcometer Common Gauge Quick Reference Guide Pages 2 3 Surface Profile Testing Page 4 Climatic Conditions Testing Pages 5 6 Dry Film Thickness Testing Page 7 Porosity Testing Ph 1300 5...

Page 2: ...Surface Profile Gauge E224C TI E224C TS Elcometer 224 Model T Digital Surface Profile Gauge Range 0 500 m 0 20mils Resolution 1 m 0 1mil Accuracy 5 or 5 m 0 2mil Part Number Probe Design T224C500US F...

Page 3: ...Range TESC Coarse 20 64 m TESXC X Coarse 38 115 m TESXC PLUS X Coarse Plus 116 147 m TESBT Burnishing Tool needed to leave impression TESGMET Testex Metric Dial Thickness Gauge microns PHCAL GMET 730...

Page 4: ...and statistic review Standard Gauge Last 10 records Top Gauge 25 000 records in 999 batches Accessories T31920162 Magnetic Surface Temperature Probe 40 to 200 C 40 to 392 F T9996390 Liquid Temperatur...

Page 5: ...FT Gauge Integral Model Options Built in Probe Scale 1 Range 0 1500 m 0 60mils Accuracy 1 3 or 2 5 m 0 1mil Model E Model B Model S Model T Elcometer 456 Ferrous Integral A456CFEI1 A456CFBI1 A456CFSI1...

Page 6: ...99921325 USB Cable Scale 1 Range 0 1500 m 0 60mils Accuracy 1 3 or 2 5 m 0 1mil Probe Design Ferrous Non Ferrous Dual Probe Straight T456CF1S T456CN1S T456CFNF1S Right Angle T456CF1R T456CN1R T456CFNF...

Page 7: ...Voltage 9V 67 5V and 90V Coating Range Max 500 m 20mils 500 m 20mils Pinhole Inspector s Kit The complete pinhole detection kit T27018191 Elcometer 266 Holiday Detector Requires Probe Handle see Belo...