background image

Eng

lish

Elcometer

2210 

• 

2215 

• 

2310

2434 

• 

2435 

• 

2436 

• 

2437

Viscosity Dip Cup

Operating Instructions

2210_TMA_0317_00_05.fm  Page -1  Thursday, July 15, 2010  9:38 AM

Summary of Contents for Frikmar 2434

Page 1: ...English Elcometer 2210 2215 2310 2434 2435 2436 2437 Viscosity Dip Cup Operating Instructions 2210_TMA_0317_00_05 fm Page 1 Thursday July 15 2010 9 38 AM...

Page 2: ...d in a retrieval system or otherwise or translated into any language in any form or by any means electronic mechanical magnetic optical manual or otherwise without the prior written permission of Elco...

Page 3: ...2 Taking a reading 4 3 Storage 7 4 Technical specification 7 5 Maintenance 8 6 Accessories 9 7 Certification 9 8 Related equipment 10 9 Viscosity standard oils 11 10 Elcometer viscosity cups 12 2210_...

Page 4: ...P Elcometer Viscosity Dip Cups are easy to use gauges for rapid measurement of viscosity of liquids The cup is held by its handle and is dipped into the liquid to be measured The cup is removed from t...

Page 5: ...ntally sensitive manner Consult your local Environmental Authority for further guidance 1 4 CAUTION Take care to avoid damaging your viscosity dip cup Damage to the orifice scratches on the internal s...

Page 6: ...t for cups with higher mass 5 minutes will be better 4 Lift the cup vertically out of the liquid Figure 1 B and start the stopwatch the moment the top of the cup breaks the surface of the liquid 5 Wat...

Page 7: ...istokes cSt To convert from flow time s to kinematic viscosity cSt use the Elcometer 2400 Viscosity Disc see Related equipment on page 12 Alternatively use the following formula V K t c where V kinema...

Page 8: ...T C Paint Flow and Pigment Dispersion second edition John Wiley Sons New York 1979 page 82 1 1 29 Shell Cup 1 0 226 13 Zahn Cup 2a 3 5 14 Shell Cup 2 0 576 5 Zahn Cup 3a 11 7 7 5 Shell Cup 2 0 925 3...

Page 9: ...res e g ISO 9000 and other standards To check for wear use Elcometer 2410 Viscosity Standard Oilsb and measure the drain time If wear is detected contact Elcometer or your local Elcometer supplier Det...

Page 10: ...requested at the time of order as they can not be issued retrospectively 7 TECHNICAL SPECIFICATION Elcometer 2210 Zahn 2215 Lory LCH and 2310 Shell Stainless steel Elcometer 2434 5 6 7 Frikmar Anodis...

Page 11: ...0 2 2 4mm K0002410M022 60 120cSt Shell Dip Cup 4 Elcometer 2310 4 3 8mm K0002410M023 100 230cSt Shell Dip Cup 5 Elcometer 2310 5 4 6mm K0002410M024 200 460cSt Shell Dip Cup 6 Elcometer 2310 6 5 8mm K0...

Page 12: ...5 5 460 1840 K0002210M005 K0002210M005C 2215 1 1 50 1100 K0002215M001 N a 2310 1 1 ASTM D 4212 2 20 K0002310M001 K0002310M001C 2310 2 2 10 50 K0002310M002 K0002310M002C 2310 3 3 30 120 K0002310M003 K0...

Page 13: ...2437 6 5 91 326 K0002437M006 K0002437M006C 2437 4 6 188 684 K0002437M004 K0002437M004C 2437 5 8 K0002437M005 K0002437M005C a ISO 2431 supersedes DIN 53224 EN535 NBN T22 108 NF T30 070 Efflux Time Cer...

Page 14: ...Viscosity Dip Cups may also benefit from the following Elcometer products Elcometer 2410 Viscosity Standard Oils for Calibration Elcometer 2400 Viscosity Disc Elcometer 7300 Digital Stopwatch Elcomet...

Reviews: