background image

V

V

I

I

P

P

C

C

L

L

A

A

M

M

P

P

M

M

I

I

N

N

I

I

SOMMARIO

1.PRESENTATION... 

.............................................................................................................1

2. DESCRIPTION 

..................................................................................................................1

3. IMLEMENTATION-FUNCTIONAL CHARACTERISTICS.. 

...............................................1

    3.1 Reference conditions..... ..........................................……............................................3

    3.2 Voltage measurements   (V)...........................................…..............................…........3

    3.3 Audio continuity test (  ) ........................................…...................................................3

    3.4 Resistance measurement (

W

) ............................………... ..........................................4

    3.5 Semi-Conductour Test (   )..................................…......................................................4

    3.6 Current measurement (A).........................................…...............................................5

    3.7 INRUSH functions....................................................…................................................5

    3.8 Power measurement ~ (W var VA)...........................…................................................6

    3.9 Power factor calculation (PF) ...........................…........................................................7

    3.10 Frequency Measurement (Hz) ........................................….......................................7

    3.11 Phase order indication  ................................................................................................7

    3.12 Secondary Functions .................................................................................................8

            3.12.1   Display lock ..................................................................................................8

            3.12.2   Preselection of MIN/MAX mode....................................................................9

            3.12.3   Automatic compensation for cable resistance ..............................................9

            3.12.4   Automatic compensation of current measurement zer ….............................9

            3.12.5   Manual selection of AC, DC or AC+DC mode...............................................9

            3.12.6   Selections possible in continuity function......................................................9

            3.12.7   Selectione OF INRUSH function ..................................................................9

            3.12.8   Suppression of automatic stop .....................................................................9

            3.12.9   Activation of the V-Live function ...................................................................9

            3.12.10 Modification of audio indication threshold in continuity test..........................9

            3.12.11 Default configuration of the unit.......................... ..........................................9

            3.12.12 Date of last calibration carried out on unit ....................................................9

            3.12.13 Display of the internal software version ......................................................10

            3.12.14 Showing of disply segments........... ............................................................10

4. GENERAL SPECIFICATIONS 

........................................................................................10

    4.1 Dimensions and weight .............................................................................................10

    4.2 Clamp tightening capacity .........................................................................................10

    4.3 Power supply .............................................................................................................10

    4.4 Environmental parameters.........................................................................................10

    4.5 Compliance with norms .............................................................................................10

    4.6 Variations in operating range... ................................................................................. 11

    4.7 Marginal operating conditions ...................................................................................12

5. GUARANTEE

.................................................................................................................. 12

6. 

MAINTENANCE 

............................................................................................................. 12

    6.1 Changing the battery ................................................................................................ 12

    6.2 Storage ......................................................................................................................12

    6.3 Cleaning ....................................................................................................................12

7. APPENDIX

.......................................................................................................................13

Summary of Contents for VIP CLAMP MINI Series

Page 1: ...e clamp box is not properly closed Before any measurement check the proper positioning of the cables and switch When measuring current check for proper alignement of the conductor in relation to the m...

Page 2: ...ement zer 9 3 12 5 Manual selection of AC DC or AC DC mode 9 3 12 6 Selections possible in continuity function 9 3 12 7 Selectione OF INRUSH function 9 3 12 8 Suppression of automatic stop 9 3 12 9 Ac...

Page 3: ...ty measurement by use of the yellow resistance key and semi conductor test A Measurement of DC and AC voltages rms value PF Measurement of active reactive and apparent var W powers and power factor in...

Page 4: ...tal display The liquid crystal display includes the digital display of the measured values the related units and symbols Digital display 4 digits 9999 points 3 decimal points and signs DC and peak mea...

Page 5: ...V 3 Connect the assembly to the voltage source to be measured making sure if possible that this voltage does not exceed the maximum acceptable limits see table below Range switching and AC DC selecti...

Page 6: ...asuring range Accuracy 1 Resolution Open circuit voltage Protection 0 0 399 9W 1 L 2 pto 0 1 W 300 A Measuring current 3 2 V 500V AC o 750V DC or peak MIN MAX Mode Accuracy same as previous table 0 2...

Page 7: ...o in DC Repeatability of the measurement after several consecutive closings of the clamp 0 3 typical MIN MAX Mode Accuracy same as previous table 0 2 L Capture time 100 ms typ PEAK Mode Accuracy same...

Page 8: ...3f arrow on the jaws must be directed in the direction of power circulation from the source to the load In which case the sign corresponds to power consumed by the load the sign corresponds to power s...

Page 9: ...he frequency measurement is performed on the voltage signal 1 Perform a short pressing on the Hz key the display shows the frequency of the measured signal 2 Pressing again returns to the previously d...

Page 10: ...essing unlocks the display 3 12 2 Preselection of MIN MAX mode A short pressing on the HOLD key then on the MIN MAX key preselects the MIN MAX mode A second pressing on the HOLD key makes the MIN MAX...

Page 11: ...12 8 Suppression of automatic stop Hold the HOLD key pressed and bring the rotary switch from the OFF position to the position The unit emits a double beep then the symbol flashes The selected configu...

Page 12: ...x 10 s measurements 6 Battery charge indicator Flashing charge life 1 h Fixed Change battery Automatic OFF after 10 minutes with no action on the switch or the keys reactivation by switching from the...

Page 13: ...V V I I P P C C L L A A M M P P M M I I N N I I 4 6 Variations in operating range 11...

Page 14: ...t the top of the battery cover rear of the clamp and push the battery cover upwards Replace the used battery by a 9 V battery type LF22 observe the polarities Install the battery in its housing then i...

Page 15: ...V V I I P P C C L L A A M M P P M M I I N N I I APPENDIX APPENDIX 13...