At any time, a long press on the key will quit the MIN/MAX mode.If the INRUSH function was selected (see description

§ 3.7), a short pressure will return to MIN/MAX mode.

Note:

 In MIN/MAX mode, the Automatic stop function of the unit is unavailable (symbol       )

- Hz 

A short press displays the frequency of the measured signal, another press switches back to the previous value.

       This key is active only for the AAC, VAC and W functions.

 -     Short pressure:

 display backlight command.

        Automatic shutdown after 2 minutes.

        

Held pressure:

 display of estimated remaining battery power, expressed in hours (except INRUSH

        and phase order functions).

HOLD key/ switch combination 

(see description § 3.12):

- Suppression of automatic stop function

- Activation of the V-Live function

- Display of the internal software version

Yellow key/ switch combination 

(see description § 3.12):

- Modification of audio indication threshold in continuity test -Default configuration of the unit

MIN/MAX key/ switch combination

(see description § 3.12):

-Date of last calibration performed on unit

Liquid crystal display

The liquid crystal display includes the digital display of the measured values, the related units and symbols.

Digital display

4 digits, 9999 points, 3 decimal points , + and - signs (DC and peak measurement).

+ OL

:  Positive value range exceedance (> 3999 points)

-  OL:  

Negative value range exceedance

   OL:

  Unsigned value range exceedance

- - - -:  Indeterminate value (middle

Symbol display

    Flashing

, clamp power limited to approximately 1 hour

           Steady

, battery drained, clamp operation or accuracy no longer guaranteed

           Constant operation (no automatic shutdown)
            

ON

 steady when the INRUSH function is selected

            Fixed:

 Continuity measurement

            Flashing: 

V-Live function selected

HOLD   

Function active

PEAK  

ON in V and A in MIN/MAX mode if the measurement of the peak value is selected

MAX    

Indicates the display of a maximum value in MIN/MAX mode

MIN     

Indicates the display of a minimum value in MIN/MAX mode

OK     

Symbol which goes on during the phase rotation direction detection sequence 

W

, if power factor display is

selected (yellow key)

PF

     

 

Goes on steady, for switch position 

AC      M

easurement in AC manual mode

           Flashing:

 measurement in AC automatic mode

DC     Fixed:

 measurement in DC manual mode

          

Flashing:

 measurement in DC automatic mode 

 

   Semi-conductor test on position

3Ø     Power measurement on balanced 3 phases system.

2

Summary of Contents for VIP CLAMP MINI Series

Page 1: ...e clamp box is not properly closed Before any measurement check the proper positioning of the cables and switch When measuring current check for proper alignement of the conductor in relation to the m...

Page 2: ...ement zer 9 3 12 5 Manual selection of AC DC or AC DC mode 9 3 12 6 Selections possible in continuity function 9 3 12 7 Selectione OF INRUSH function 9 3 12 8 Suppression of automatic stop 9 3 12 9 Ac...

Page 3: ...ty measurement by use of the yellow resistance key and semi conductor test A Measurement of DC and AC voltages rms value PF Measurement of active reactive and apparent var W powers and power factor in...

Page 4: ...tal display The liquid crystal display includes the digital display of the measured values the related units and symbols Digital display 4 digits 9999 points 3 decimal points and signs DC and peak mea...

Page 5: ...V 3 Connect the assembly to the voltage source to be measured making sure if possible that this voltage does not exceed the maximum acceptable limits see table below Range switching and AC DC selecti...

Page 6: ...asuring range Accuracy 1 Resolution Open circuit voltage Protection 0 0 399 9W 1 L 2 pto 0 1 W 300 A Measuring current 3 2 V 500V AC o 750V DC or peak MIN MAX Mode Accuracy same as previous table 0 2...

Page 7: ...o in DC Repeatability of the measurement after several consecutive closings of the clamp 0 3 typical MIN MAX Mode Accuracy same as previous table 0 2 L Capture time 100 ms typ PEAK Mode Accuracy same...

Page 8: ...3f arrow on the jaws must be directed in the direction of power circulation from the source to the load In which case the sign corresponds to power consumed by the load the sign corresponds to power s...

Page 9: ...he frequency measurement is performed on the voltage signal 1 Perform a short pressing on the Hz key the display shows the frequency of the measured signal 2 Pressing again returns to the previously d...

Page 10: ...essing unlocks the display 3 12 2 Preselection of MIN MAX mode A short pressing on the HOLD key then on the MIN MAX key preselects the MIN MAX mode A second pressing on the HOLD key makes the MIN MAX...

Page 11: ...12 8 Suppression of automatic stop Hold the HOLD key pressed and bring the rotary switch from the OFF position to the position The unit emits a double beep then the symbol flashes The selected configu...

Page 12: ...x 10 s measurements 6 Battery charge indicator Flashing charge life 1 h Fixed Change battery Automatic OFF after 10 minutes with no action on the switch or the keys reactivation by switching from the...

Page 13: ...V V I I P P C C L L A A M M P P M M I I N N I I 4 6 Variations in operating range 11...

Page 14: ...t the top of the battery cover rear of the clamp and push the battery cover upwards Replace the used battery by a 9 V battery type LF22 observe the polarities Install the battery in its housing then i...

Page 15: ...V V I I P P C C L L A A M M P P M M I I N N I I APPENDIX APPENDIX 13...