RCL03 / RCL04 Mini Receiver
RCL03
N
C
1
N
C
2
N
O
1
N
O
2
C
O
M
1
C
O
M
2
IN
1
IN
2
LED
CH2
CH1
Aerial
TA2
TA1
J1
1
2
3
4
5
RCL04
LED
CH2
CH1
Aerial
TA2
TA1
J1
1
2
3
4
5
Models
RCL03E5002-01
Degree of protection IP 20
RCL04E5002-01
Degree of protection IP 65
Scope of Delivery
- Mini Receiver
- Mounting accessories (
RCL03:
Adhesive
pad,
RCL04:
Screws and anchors)
- Operating instructions
Safety Advice
Carefully read through these
instructions before connecting
and operating the receiver!
Caution! Observe the permissible sup-
ply voltage and the max. contact rating!
Have faulty radio controls checked by the
manufacturer!
Do not make any unauthorized alterations
or modifications to the receiver!
Intended Use
The unit may only be operated with safety
extra low voltage (SELV) and may only be
used as a radio control for switching devices
with safety extra low voltage (SELV).
The manufacturer shall not be liable for any
damage caused by improper or non-intended
use.
Function
The RCL03/RCL04 Easywave Mini-Receiver
can be operated in a voltage range of 12-
24 V AC/DC.
Four operating modes are available:
- Dead man’s mode (Factory setting)
- Roller blind motor control
- ON/OFF
- Impulse (1 second).
2 potential-free relay outputs may be
switched via 2 separate radio channels.
A total of 32 different Easywave radio trans-
mission codes can be memorized.
It is also possible to connect one external
impulse button for each channel which can
then be used to switch the corresponding
relay according to the selected operating
mode.
Using the Mini-Receiver
Operating Modes
The radio control can be operated in four
different operating modes with Easywave
hand transmitters, wall transmitters as well
as radio timers:
A
B
C
A
B
D
C
A
B
D
A B
•
Dead man’s mode
Each relay can be switched separately.
The relay is triggered as long as the
corresponding transmitter button or the
corresponding external impulse button is
pressed (at transmitter button operation
max. 36 secs).
•
Roller blind motor control
Controlling roller blind motors (2-button
operation):
Button
Function
Transmitter button
A or C or Impulse
button CH1
- OPEN
- STOP for CLOSE
direction
Transmitter button
B or D or Impulse
button CH2
- CLOSE
- STOP for OPEN
direction
The relay switches off after 90 seconds
automatically.
•
ON/OFF
Each relay can be switched separately:
Button
Function
Transmitter button A or C or
Impulse button 1
st
pressing
ON
Transmitter button B or D or
Impulse button 2
nd
pressing
OFF
•
Impulse (1 Second)
If a transmitter button or an external im-
pulse button is pressed, the correspond-
ing relay is triggered for 1 second.
Mounting and Connecting
1. Remove the housing cover.
2. Using the mounting accessories supplied,
mount the receiver on a suitable location.
Mounting Advice:
The reception quality can be affected by
a number of factors
:
- location
- equipment and systems without
interference suppression
- other transmitters within the frequency
range
- atmospheric conditions and other
factors.
Do not mount the receiver near the floor
or near large metal objects!
The maximum length of all connecting
cables may not exceed 3 m.
In case of malfunctions, contact your re-
tailer or the manufacturer.
3. Select the desired operating mode with
jumper J1:
1
2
3
4
5
J1
in position
1-2
:
Dead man’s mode
1
2
3
4
5
J1
in position
2-3
:
Roller blind motor control
1
2
3
4
5
J1
in position
3-4
:
ON/OFF
1
2
3
4
5
J1
in position
4-5
:
Impulse (1 second)
4. Connect the supply voltage and the
safety extra low voltage devices to be
switched as follows:
Operating modes „Dead man’s mode“,
„ON/OFF“ and “Impulse
(1 second)”
N
C
1
N
C
2
N
O
1
N
O
2
C
O
M
1
C
O
M
2
IN
1
IN
2
- Supply voltage
(12-24V AC/DC): IN1, IN2
(at DC: Polarity is arbitrary)
- Device 1 (at relay 1 / channel 1):
NO1 - COM1: NO contact
NC1 - COM1: NC contact
- Device 2 (at relay 2 / channel 2):
NO2 - COM2: NO contact
NC2 - COM2: NC contact
Operating mode „Roller blind motor
control“
The receiver may only be operated with
12-24 V DC in this mode.
-
12-24 V DC +
N
C
1
N
C
2
N
O
1
N
O
2
C
O
M
1
C
O
M
2
IN
1
IN
2
M