GB
Wired Weather Sensor
SW01-W
wind
SWS01-W
wind-sun
SWSR01-W
wind-sun-rain
Model
SW01-W01-01
wind
SWSR01-W01-01
wind/sun/rain
SWS01-W01-01
wind/sun
Coding:
EasywaveSens
Power supply:
230 V AC ~ 50 Hz
Connected load:
4 VA
Degree of protection:
IP44
Class of protection:
II
Data line:
max. 25m
Operating temperature:
-25 °C bis +55 °C
Measuring ranges:
- wind
3 km/h to 50 km/h
- light intensity
1 lx to100 klx
Dimensions (BxLxH):
- sensor
52/131x200x73 mm
- plate
121x52x30 mm
Weight:
260 g
Technical Details
- 1 Sensor SWSR01
- 1 Mounting plate
- 2 Cover caps
- 1 Terminal cover
- 1 Terminal block 2-pin
- 2 Hex bolts 6x40
- 2 Washers
- 2 Dowels SX8
- 1 Hexagon socket screw M6x65
- 1 Lock nut M6
- 2 Pan head screws
- Operating instructions
Scope of Delivery
The weather sensors are only for wire trans-
mission of weather data to the Easywave radio
receivers RCJ05, RCM04 or CM01 for weat-
her-dependent control of awnings.
The manufacturer shall not be liable for any da-
mage caused by improper or non-intended
use!
Intended use
Safety Advice
Before you connect and operate
the device, please read these
operating instructions carefully!
The electrical installation must only be
carried out by a qualified electrician (please
refer to VDE 0100-200 and/or relevant
national regulations).
Repair, maintenance and cleaning
work must only be carried out after
the device has been disconnected
from the mains power supply!
Have faulty device checked by the
manufacturer!
Do not make any unauthorized alterations or
modifications to the device!
Keep the device out of the reach of children.
-
-
-
-
-
Function
The weather sensors continuously detect wind
strength, light intensity and rain data and send
this data via a wired connection to the control
RCM04, RCJ05 or CM01. There, the data is
evaluated and the awning is controlled accor-
dingly.
The „gastronomy function“ integrated in the
SWSR01 also allows the awning to be opened
in rainy weather, contrary to the standard rain
function.
When selecting a location for the device, please
ensure that the light sensor and surface of the
rain sensor are not covered or placed in the
shade. Slipstreams should also be avoided.
We recommend assembling the
weather sensor at a height of above
2.50 m. The installation height may by
no means fall below 1.70 m.
For each installation, please ensure that
the weather sensor is horizontal or is
tilted downwards slightly at the front.
The impeller must always face
downwards.
1. Screw the mounting plate to the installation
site with the screws and dowels.
2. Insert the current and voltage-free mains
cable and the Sensor cable through the
terminal cover from below and clamp the
wires to the terminal block provided.
3. Attach the terminal to the pin connector on the
printed circuit board and securely fix the
terminal cover (see also „Electrical connecti-
on“).
4. Place the sensor between the brackets of the
Mounting plate and attach it with hexagon
socket screw and the lock nut. Attach the
cover caps.
Mains power cable
(not included in supply package)
Warning:
the “Electrical connection”
section of this document must be
observed!
Terminal block 2-pin
Cover cap
Mounting plate
Installation
Light sensor
(only SWSR01-W and
SWS01-W)
Rain sensor
(only SWSR01-W)
Vane
SWSR01-W
Terminal cover
Sensor connection cable (data cable)
max. permitted Line 25 m
(not included in supply package)
Fig. 1