8-2
ELECTRICAL SYSTEM
Generators / Charger
All electrical equipment fitted in your new
campervan can be run from either a
controlled generator or charger whose output
is maintained between 11volts and 14volts.
At least once every 3 years, the campervan
electrical installation should be inspected and
tested and a report on its condition obtained,
as prescribed in British Standard BS7671.
230v POWER SUPPLY
Mains Unit
The Mains Unit replaces the conventional
fuse box. Similar, but larger ones are often
fitted in new houses. The unit, normally
located on the front bed box, gives overloads
and earth leakage protection for the 230V
electrical supply in your campervan.
For normal operation all switches on the unit
need to be in the ON position. The switches
on the left of the unit are known as MCB’s
(miniature circuit breakers). These take the
place of the conventional fuse but are more
convenient. In the event of a fault the MCB
‘trips’ i.e. automatically moves to the OFF
position. After elimination of the fault the
MCB can be re-set by switching to the ON
position (against the spring pressure in an
upwards direction). If an earth fault develops,
or a person was to touch a live piece of
equipment, the leakage of current to earth
should immediately operate the RCD
(residual current device) and ‘trip’ the main
switch, to the OFF position. This switch can
only be re-set after elimination of the fault.
Please note:
In case of difficulty, consult an
approved electrical installation contractor
(who may be the local electricity board). It is
dangerous to attempt modifications and
additions yourself.
CAUTION:
Lamp holder-plugs (bayonet- cap
adaptors) should not be used under any
circumstances.
Resetting the RCD
To re-set, operate the switch as for MCB’s.
Periodically, the RCD should be checked by
operating the test button marked ‘T’. The unit
should immediately switch to the OFF
position. If the unit does not switch off then a
qualified electrician should be consulted. If
the unit does switch off, the test is complete
and the switch can be re-set restoring the
supply back to normal.
Please note:
Simultaneous operation of all
of the 230V mains electrical equipment may
not be possible. A typical UK site mains hook-
up point provides a maximum output of 16
amps and on some continental sites the
available output may be as low as 5 amps. If
your loading exceeds the site supply it may
trip the site circuit breaker. Please check the
available mains output with your site
operator. The following items need to be
added together if used simultaneously.
230V mains equipment typical consumption
figures:
• Refrigerator ............................... 0.50 amps
• Charger ....................................... 2.2 amps
• Water heater ............................... 3.9 amps
• Blown air heaters ........................ 8.5 amps
• Colour TV .................................. 3.33 amps
AUTOMATIC CHARGING SYSTEM
The battery charger will operate automatically
when the campervan is connected to the
mains outlet on a campervan site.
Note:
The charging unit only charges the
leisure battery not the vehicle battery.
When the campervan engine is running the
12V system will not operate with the
exception of the 12V refrigerator.
Summary of Contents for Autoquest 2021
Page 10: ...4 2 MOTORWAY HANDLING ...
Page 12: ...5 2 ARRIVING ON SITE ...
Page 20: ...7 4 GAS SAFETY ADVICE ...
Page 24: ...8 4 ELECTRICAL SYSTEM MAINS UNIT CAMPERVAN ...
Page 67: ...9 43 HOW TO USE YOUR CAMPERVAN S EQUIPMENT ...
Page 72: ...9 48 HOW TO USE YOUR CAMPERVAN S EQUIPMENT HOW TO MAKE UP YOUR BEDS Campervan Day and Night ...
Page 76: ...10 2 SECURITY ...
Page 82: ...12 2 STORAGE ...
Page 86: ...13 4 WARRANTY ...
Page 88: ...14 2 CAMPERVAN CONSTRUCTION ...
Page 89: ...15 1 ELECTRICAL DRAWINGS ELECTRICAL DRAWINGS CAMPERVAN ...
Page 90: ...15 2 ELECTRICAL DRAWINGS ...
Page 96: ...17 4 GLOSSARY ...
Page 104: ...19 2 CHANGE OF OWNERSHIP ...
Page 106: ...20 2 CHANGE OF ADDRESS ...