12
1.5 System Installation
Device installation and Pre-operation:
1.
Fasten the system in the box using fastening holders
2.
Place SIM card in the holder but make sure that SIM card PIN code is disabled. (PIN code can be disabled by putting SIM card
into mobile phone and following proper menus). SIM card should not have any remaining SMS messages.
3.
Connect the antenna (the device cannot be turned on without antenna).
4.
Using RJ11 connection on ET07P unit connect telephone line to the telephone which will be used or to private branch
exchange station (PBX). It is necessary to perform setting configurations in PBX system so that all calls outgoing to mobile
connection networks are operated through the communicator ET07P.
5.
When AC power supply (ground transformer) is used, connect according to circuit no. 3. In this case you do not need to
connect any other power supplies.
6.
The system should start in less than a minute. STATUS indicator should be blinking every five seconds indicating connection
to GSM network. If the indicator is blinking very frequently, i. e., several times per second, it is possible that SIM card is
inserted incorrectly or PIN code request is not disabled.
Dialling Telephone Numbers
If the communicator ET07P is connected directly to a stationary telephone, the calls will be made as if you are calling from a mobile
telephone. In such a case you only need to dial telephone number as you were using mobile phone and dial „00“ instead of prefix „+“.
When connecting communicator ET07P to private branch exchange station (PBX) it is possible to configure settings in PBX system
so that only calls made to mobile networks are operated through the communicator ET07P. Telephone number should be dialled the same
way as described in the previous situation.
Fuse 500 mA
~230V 50Hz
AC/DC
~10-24V
Picture 3