EWK1 - Wireless Key-Fob

Key-fob EWK1 – is a wireless device intended to arm and disarm ELDES alarm system, to open and close the gates or to control any other 

device connected to the alarm system. Wireless key-fob EWK1 is compatible with ELDES wireless alarm systems, therefore user can easily 

bind it to the alarm system using 

ELDES Configuration Tool

 software or sending a corresponding SMS command. EWK1 key-fob features 

four configurable buttons intended to operate according to individual needs. After the button is pressed, EWK1 internal buzzer’s sound 

signal confirms a transferred command to ELDES alarm system via wireless connection. The status of the sent command can be checked 

by attempting to receive the feedback signal from the alarm system. This can be performed by pressing down the same button and 

holding it for 3 seconds. 3 short sound signals indicate a successfully carried out command while 1 long beep stands for failed command 

and feedback signal failure. By default one pair of buttons is already configured to arm and disarm the alarm system.

NOTE: 

Fig. No. 1 reflects the default EWK1 button configuration. All key-fob buttons are configurable according to individual needs. 

1. Package Content 

1. EWK1 ...................................................................................... qty. 1
2. CR2032 3V Lithium Battery ........................................... qty. 1
3. User Manual ........................................................................ qty. 1

2. Technical Specifications

2.1 Electrical & Mechanical Characteristics

Battery Type

CR2032 Lithium

Battery Voltage; Capacity

3V; 240 mAh

Quantity of Batteries

1

Battery Operation Time

~18 months*

Wireless Transmitter-Receiver Frequency

868 Mhz

Range of Operating Temperatures 

-20...+55ºC

Wireless Key-fob Dimensions

54 x 42 x 13 mm

Wireless Communication Range

Up to 30 meters in premises; up to 150 meters in open areas

Compatible with Alarm Systems

ELDES Wireless 

* This operation time depends on different conditions and may vary.

Fig. No. 1

The virtual zones of ELDES alarm system are intended for 

EWK1 button configuration. Please, refer to software’s 

ELDES 

Configuration Tool 

HELP section for more details. It is possible 

to connect up to 5 EWK1 devices to ELDES alarm system at a 

time. The maximum wireless connection range is 150 meters 

(in open areas).

Optional 

funcionality

Optional 

funcionality

Arm the 

system

Disarm the 

system

Main Features:

• 

Alarm system arming & disarming;

• 

Panic button;

• 

PGM output control;

• 

Sound indication by built-in mini buzzer.

Summary of Contents for EWK1

Page 1: ...WIRELESS KEY FOB EWK1 BELAIDIS PULTELIS ...

Page 2: ...feedback signal failure By default one pair of buttons is already configured to arm and disarm the alarm system NOTE Fig No 1 reflects the default EWK1 button configuration All key fob buttons are configurable according to individual needs 1 Package Content 1 EWK1 qty 1 2 CR2032 3V Lithium Battery qty 1 3 User Manual qty 1 2 Technical Specifications 2 1 Electrical Mechanical Characteristics Batter...

Page 3: ...d press Add button see Fig No 5 The device can also be bind by sending a corresponding command via SMS message For more details please refer to the software s HELP section and ELDES alarm system installation manual 6 Press any EWK1 button several times until the device is successfully bound Upon the successful binding process EWK1 icon Battery Level and Signal Level becomes visible in ELDES Config...

Page 4: ... status can be monitored in real time using ELDES Configuration Tool software 6 Restoring Default Parameters 1 Remove the battery from EWK1 key fob 2 Press and hold button 3 Insert the battery back to EWK1 4 Hold the button pressed until LED indicator provides several short flashes 5 Release button 6 Parameters restored to default 7 Additional Information Limited Liability The buyer must agree tha...

Page 5: ... by ELDES UAB ELSDES UAB reserves the right to update or modify this document and or related products without a warning Hereby ELDES UAB declares that this EWK1 wireless key fob is in compliance with the essential requirements and other relevant provisions of Directive 1999 5 EC The declaration of conformity may be consulted at www eldes lt The WEEE Waste Electrical and Electronic Equipment markin...

Page 6: ...eįvykdytą komandą ir negautą grįžtamąjį ryšį Pagal gamyklinę konfigūraciją viena mygtukų pora jau yra sukonfigūruota įjungti ir išjungti apsaugą PASTABA 1 pav pavaizduota EWK1 mygtukų gamyklinė konfigūracija Visų pultelio mygtukų funkcijos gali būti keičiamos pagal poreikius 1 Pakuotės sudėtis 1 EWK1 1 vnt 2 CR2032 3V Lithium baterija 1 vnt 3 Vartotojo vadovas 1 vnt 2 Techninė specifikacija 2 1 El...

Page 7: ... 5 pav Belaidis ryšys taip pat gali būti aktyvuotas nusiuntus atitinkamą SMS žinutę Plačiau apie tai skaitykite programinės įrangos HELP skyriuje ir ELDES apsaugos sistemos instaliavimo vadove 6 Aktyvuodami belaidį ryšį keletą kartų spustelkite bet kurį EWK1 mygtuką Sėkmingai aktyvavus belaidį ryšį tarp EWK1 įren ginio ir apsaugos sistemos ELDES Configuration Tool programinės įrangos Wireless Devi...

Page 8: ...šimkite bateriją iš EWK1 2 Paspauskite ir laikykite mygtuką 3 Įstatykite atgal bateriją į EWK1 4 Laikykite mygtuką kol LED indikatorius keletą kartų trumpai sumirksės 5 Paleiskite mygtuką 6 Gamykliniai parametrai atstatyti 7 Papildoma informacija Atsakomybės ribojimas Pirkėjas sutinka kad sistema sumažina gaisro plėšimo vagystės ar kitą riziką tačiau tai nėra draudimas ar garantija kad paminėti ve...

Page 9: ...umento dali be išankstinio raštiško UAB ELDES sutikimo UAB ELDES pasilieka teise be išankstinio ispejimo tobulinti ar keisti bet kuriuos dokumente paminetus gaminius taip pat pati dokumenta UAB ELDES deklaruoja kad belaidis pultelis EWK1 atitinka esminius reikalavimus ir kitas 1999 5 EC direktyvos nuostatas Jos atitikties deklaracija galima rasti šiame tinklalapyje www eldes lt Pagal WEEE direktyv...

Page 10: ...ducts Inc iButton is a registered trademark of Maxim Integrated Products Inc Dallas is a registered trademark of Maxim Integrated Products Inc Ademco Contact ID is a registered trademark of Pittway Corporation Microsoft Windows and Vista are registered trademarks of Microsoft Corporation ...

Reviews: