V. CALCULATIONS
If the test temperature is within +3
°
or -5
°
F of 77
°
F (+ 1.7
°
or - 2.8
°
C of 25
°
C),
the following equation can be used to determine the maximum specific gravity of
the sample, with an error of 0.001 points or less due to thermal effects:
Where:
A = Mass of the dry sample in air (grams)
D = Mass of container when filled with water at 77
°
F (25
°
C) (grams)
E = Mass of container filled with both water and sample at 77
°
F (25
°
C)
(grams)
Note: If the test temperature differs significantly from the recommended
77
°
F (25
°
C), the formula should be adjusted for thermal effect as
follows:
Where:
A =
Mass of dry sample in air (grams)
F =
Mass of pycnometer filled with water at test temperature (grams)
G = Mass of pycnometer filled with both water and sample at test
temperature (grams)
H =
Correction for thermal expansion of bitumen (grams)
dw = density of water at test temperature, Mg/m
3
0.9970 = density of water at 77
°
F (25
°
C), Mg/m
3
Values of H and dw may be obtained from the ASTM graphs in Fig. 2. For more
details, see ASTM D 2041.
VI. TROUBLESHOOTING