Safety
General precautions
Do not inhale concentrated vapours. Their concentration in the atmo-
sphere should not exceed the minimum preset values and should be
maintained below the professional threshold. Being more weighty than
the air, the vapour concentrates on the bottom, in narrow areas. There-
fore, the exhaust system must work at low level.
Respiratory system protection
If you are in doubt about the concentration in the atmosphere, it is recom-
mended to wear a respirator approved by an accident-prevention Author-
ity, of the independent or oxygen type.
Storage
Cylinders must be stored in a cool, dry and properly ventilated storage
area away from heat, flames, corrosive chemicals, flumes, explosives
and be otherwise protected from damage. Keep a temperature below
52°C.
It is important to wear protective clothing and a respirator. Stop the
source of the leak, if you can do this without danger. Negligible leaks can
be left evaporating under the sun, providing that the room is well venti-
lated. Considerable leaks: ventilate the room. Reduce the leak with sand,
earth or other absorbing substances. Make sure that the liquid does is
not channelled into gutters, sewers or pits where the vapours are likely to
create a stuffy atmosphere.
Protective clothing
Wear overalls, protective gloves and goggles or a mask.
Accidental release measures
Disposal
The best method is recovery and recycling. If this method is not practi-
cable, dispose according to an approved procedure, that shall ensure
the absorption and neutralization of acids and toxic agents.
Fire fighting information
R410A: Not flammable in the atmosphere.
Cylinders
The cylinders, if exposed to fire, shall be cooled by water jets; otherwise,
if heated, they may explode.
Protective fire fighting equipment
In case of fire, wear an independent respirator and protective clothing.
English
Summary of Contents for MQH 10T
Page 1: ...Zertifizierungsstelle Organismo Notificado No 0035 Библиотека СОК ...
Page 2: ...I X English ...
Page 42: ...VII Appendix A MQH 10T 12 14 16 18 C27019300 04 Factory Wired Field Wired Field Wired ...
Page 44: ...IX Appendix B Exploded View MQH 06 08M 08T ...
Page 45: ...X Appendix B MQH 10M 10T 12 14 16 18 ...
Page 46: ......
Page 47: ...Electra Air Conditioning shenzhen Co Ltd 2 Wuhe Avenue S Bantian Buji shenzhen China ...