INSTALLATION GUIDE

!

COPYRIGHT

Electrex is a trademark of Akse S.r.l. All rights reserved.
It  is  forbidden  to  duplicate,  adapt,  transcript  this  document  without  Akse  written
authorization, except when regulated accordingly by the Copyright Laws.

WARRANTY 

This product is covered by a warranty against material and manufacturing defects for a 24
months period from the manufacturing date.
The warranty does not cover the defects that are due to: 
• Negligent and improper use  
• Failures caused by atmospheric hazards 
• Acts of vandalism 
• Wear out of materials
• Firmware upgrades
Akse reserves the right, at its discretion, to repair or substitute the faulty products   
The warranty is not applicable to the products that will result defective in consequence of
a negligent and improper use or an operating procedure not contemplated in this manual. 

RETURN AND REPAIR FORMALITIES

  

Akse accepts the return of instruments for repair only when authorized in advance. The
transport costs are at customer charge. 

RE-SHIPPING OF REPAIRED PRODUCT

  

The terms for re-shipment of repaired products are ex-works, i.e. the transport costs are
at customer charge.
Products returned as detective but found to be perfectly working by our laboratories, will
be charged a fl at fee to account for checking and testing time irrespective of the warranty
terms.

SAFETY

 

This instrument was manufactured and tested in compliance with IEC 61010-1 CAT III -
300V class 2 standards  for operating voltages up to 300 VAC rms phase to neutral. 
In order to maintain this condition and to ensure safe operation, the user must comply with
the indications and markings contained in the following instructions: 

• When the instrument is received, before starting its installation, check that it is

intact and no damage occurred during transport. 

•  Before  mounting,  ensure  that  the  instrument  operating  voltages  and  the  mains

voltage are compatible then proceed with the installation. 

• The instrument power supply needs no earth connection. 
•  The  instrument  is  not  equipped  with  a  power  supply  fuse;  a  suitable  external

protection fuse must be foreseen by the contractor. 

•  Maintenance  and/or  repair  must  be  carried  out  only  by  qualifi ed,  authorized

personnel 

• If there is ever the suspicion that safe operation is no longer possible, the instrument

must be taken out of service and precautions taken against its accidental use. 

Operation is no longer safe when:
•There is clearly visible damaged. 
•The instrument no longer functions. 
•After lengthy storage in unfavorable conditions. 
• After serious damage occurred during transport

The instruments must be installed in respect of all the local regulations.

OPERATOR SAFETY

Warning:

  Failure  to  observe  the  following  instructions  may  lead  to  a  serious  danger  of

death.

• During normal operation dangerous voltages can occur on instrument terminals and

on  voltage  and  current  transformers.  Energized  voltage  and  current  transformers
may generate lethal voltages. Follow carefully the standard safety precautions while
carrying out any installation or service operation.

• The terminals of the instrument must not be accessible by the user after the installation.

The  user  should  only  be  allowed  to  access  the  instrument  front  panel  where  the
display is located.

• Do not use the digital outputs for protection functions nor for power limitation functions.

The instrument is suitable only for secondary protection functions.

• The instrument must be protected by a breaking device capable of interrupting both

the power supply and the measurement terminals. It must be easily reachable by the
operator and well identifi ed as instrument cut-off  device.

• The instrument and its connections must be carefully protected against short-circuit.

Precautions:

 Failure to respect the following instructions may irreversibly damage to the

instrument.

• The outputs and the options operate at low voltage level; they cannot be powered by

any unspecifi ed external voltage.

• The application of currents not compatible with the current inputs levels will damage

to the instrument.

Further documentation may be downloaded from our web site www.electrex.it.

This document is owned by company AKSE that reserves all rights. 

DECLARATION OF CONFORMITY

 

Akse hereby declares that its range of products complies with the following directives EMC
2014/30/EU,  2014/35/EU    and  complies  with  the  following  product’s  standard  CEI  EN
61326 - Ed. 2.0 (2012) – IEC 61326 - Ed. 2.0 (2012), CEI EN 61010- Ed. 3 (2010) – IEC
61010- Ed. 3 (2010). The product has been tested in the typical wiring confi guration and
with peripherals conforming to the EMC directive and the LV directive.

Atto RCM D4 ECT

MODELS

PFA74D1-D2-B

ATTO RCM D4 ECT RS485 230÷240V 2DI 2DO 
4COMMON TRANSDUCER / ANALYZER

 

2

1

LED

LED description:

LED (1)

A green LED pulses indicating the operation of the instrument

LED (2)

Two LEDs pulsate indicating the communication activity of the RS485 port (red 
TX LED, green RX LED)

MECHANICAL CHARACTERISTICS

Case

Self-extinguishing plastic material class V0

Protection degree

IP40 on front panel

Size

70 x 90 x 58 mm (4 DIN modules)

VOLTAGE INPUTS

Direct

Up to 300 Vrms phase-neutral
or 519 Vrms phase to phase
Overload: 900 Vrms phase to phase for 1 sec

Power supply

230//- 10% 50/60Hz

Self consumption

 < 2,5VA 

Summary of Contents for Atto RCM D4 ECT

Page 1: ...s After serious damage occurred during transport The instruments must be installed in respect of all the local regulations OPERATOR SAFETY Warning Failure to observe the following instructions may lead to a serious danger of death During normal operation dangerous voltages can occur on instrument terminals and on voltage and current transformers Energized voltage and current transformers may gener...

Page 2: ... IEEE754 V 30225 Phase to Neutral Voltage RMS Amplitude U3N Float IEEE754 V 30233 Phase Current RMS Amplitude I1 Float IEEE754 A 30235 Phase Current RMS Amplitude I2 Float IEEE754 A 30237 Phase Current RMS Amplitude I3 Float IEEE754 A SETUP SEQUENCE PARAMETERS VALUES AVAILABLE DEFAULT RS 485 ADDR 485 address 1 247 27 COM Baud rate 2400 4800 9600 19200 38400 38400 COM Data Bit 7 or 8 8 COM Parity N...

Page 3: ...tial channel S1 S2 S1 S2 S1 S2 CH1 CH2 CH3 L1 L2 1P2W 2P2W 3P3W B Use cables with max cross section of 2 5 mm2 if stranded 4 mm2 if rigid and connect them to the terminals marked VOLTAGE INPUT on the instrument according to the applicable diagrams that follow VOLTAGE CONNECTION U1 U2 U3 N VOLTAGE INPUT L N U1 U2 U3 N VOLTAGE INPUT L1 L2 L3 N U1 U2 U3 N VOLTAGE INPUT L1 L2 L3 U1 U2 U3 N VOLTAGE INP...

Page 4: ... 924 244 Fax 39 0522 924 245 info akse it www akse it P I 01544980350 R E A 194296 Cap Soc Euro 85 800 00 i v Subject to modification without notice Edition 2020 09 03 ENG0351 Made in Italy Pensato progettato e prodotto in Italia Engineered and manufactured in Italy ...

Reviews: