Operating instructions

TEI-1 OPERATING INSTRUCTIONS

Each radiator has a temperature sensor
installed on the underside of the
radiator. This is designed to accurately
determine the room temperature – note
that this should protrude 50 to 70 mm
from the locating screw.

The TEI-1 is operated by turning the control knob. The temperature can be regulated
from approx. 10°C to 30°C, including a frost protection setting of approx. 5°C.

setting 

¾

approx. 5°C (frost protection)

setting between 

¾

 and 1: 

approx. 10°C

setting 4: 

approx. 20°C

setting 6: 

approx. 30°C

The red indicator above the control knob indicate the heating status:

LED lit:

 

heating on or the set temperature has not been reached.

LED not lit: 

heating off or the set temperature has been achieved.

CAUTION

 - Forced turning beyond the end settings of the control knob will cause

damage to the thermostat components and as such will invalidate the warranty.

5.

Operating safety

This appliance complies with the European Standards EN 60 335-1, EN 60 335-2-61, EN
61000-3-2, EN 61000-3-3, EN 55014 and EN55104 for Safety & Electromagnetic
Compatibility. These standards cover the requirement of the EMC Directives 89/336 &
73/23

RADIATOR POSITIONING

 -  A minimum clearance of 150mm to the front of the

radiator is essential for safety, however to enable the radiator to attain its maximum
performance ensure that any furniture or other obstruction is not placed closer than
250mm.

THESE INSTRUCTIONS SHOULD BE READ CAREFULLY AND RETAINED FOR FUTURE
REFERENCE

IMPORTANT SAFETY INFORMATION

CAUTION - THE SURFACE OF THIS RADIATOR CAN BE HOT.

The surface temperatures of this radiator are within the requirements of EN60-335 the
European Standard covering the safety requirements of electric heating appliances, and
momentary contact with any part of the radiator should not cause injury.
However, in order to be effective, radiators of any type do get hot, especially around
the air outlet grille.

Corner equipment below

Summary of Contents for Electric Combination Radiators

Page 1: ...Y AND RETAINED FOR FUTURE REFERENCE BE SURE TO OBSERVE ALL LABELS AND WARNINGS ON THE APPLIANCE The Electric Heating Company Ltd Unit 40 Block 5 Third Road Blantyre Industrial Estate Blantyre Glasgow...

Page 2: ...electrician in accordance with I E E Regulations for Electrical Equipment The radiator is fitted with a standard UK 3 pin plug that can be directly connected to an electrical socket Care must be take...

Page 3: ...floor 80 mm Cover plate combustible covering installed on top of it 150 mm Cover plate non combustible covering installed on top of it 100 mm Please note that our IPX4 rated models should be used in...

Page 4: ...d Radiant heat for your added comfort The radiators can be simply plugged in to a Standard socket or Hard wired to an existing spur connection The range has the flexability of being Wall mounted or fr...

Page 5: ...ddition to the radiator body there should be a top grille a pair of mounting brackets four suspension hooks a set of mounting screws plugs and an instruction manual 2 Check page 3 of this manual to fi...

Page 6: ...e to locate the studding and use the No 10 size woodscrews provided Where it is not possible to locate the studding use Hollow wall anchors and securely fasten the brackets to the plasterboard when th...

Page 7: ...radiators come complete with a TEI1 thermostat for room temperature control For single radiator installations please follow the instructions outlined in section 8 10 EHC CONTROL BOX installations For...

Page 8: ...EHC Electric Combination Radiators Installation and technical manual Page 8 3 Installation cont...

Page 9: ...ingle radiator installations b Locate the TEI 8 digital room thermostat on a suitable wall in the same room as the radiator c Configure the TEI 8 digital room thermostat and TEI 5 receiver located on...

Page 10: ...the thermostat components and as such will invalidate the warranty 5 Operating safety This appliance complies with the European Standards EN 60 335 1 EN 60 335 2 61 EN 61000 3 2 EN 61000 3 3 EN 55014...

Page 11: ...ve the radiator without first seeking specialist advice If you are not happy that the radiator has been securely fixed please inform your installer UNDER NO CIRCUMSTANCES SHOULD YOU ATTEMPT TO MOVE TH...

Page 12: ...d be taken to wipe over with a damp cloth Do not use abrasive cleaning powders or furniture polish Discoloration of wall finishes can sometimes occur immediately above a radiator due to the properties...

Page 13: ...ory radiators Model No Colour Rating BTUs Width mm Height mm Depth mm Weight kg EH500 68 34 500W EHC ELECTRIC CONSERVATORY RAD White 1706 680 340 70 21 EH1000 85 34 1000W EHC ELECTRIC CONSERVATORY RAD...

Page 14: ...uest one of our free Product guide and Installation DVDs Tel 01698 820533 Fax 01698 825697 info electric heatingcompany co uk www electric heatingcompany co uk The Electric Heating Company Ltd Unit 40...

Reviews: