background image

VI.

 1 

Tube complement

  

Electric Signal MMXV AD

Page 31

Delta Transconductace band Compressor

User Manual

Page 32

Tubes for replacement can be obtained from our

factory.

The Delta Transconductance band compressor 

uses the following thermionic tubes:

 

 

12X 

6ba6/5749/6k4p 

Compression

 

3X 

6H30   Input/output

 

2X 

6H2p(-ev/-er)  

Mixing

 

4X 

12AT7/ECC83 

PI/tonecontrol

Notify that the remote cutoff tubes, responsible

for the compression(6ba6/5749/6k4p) need to 

be matched pairs. The 5749W (wich comes with

the compressor) is an joint Army Navy electron 

tube from General Elecric.

The two 6h30 for the output need to be 

matched triodes.

The Delta Transconductance band compressor 

comes with two russian milspec 6h2p-er, 

responsible for mixing, if desired to use an 

european ecc81or an nowadays 12ax7 make 

use of a ecc to 6h2p socket (contact electric 

signal for more information)

Not every ECC83 is usable due to the maximum

rating specifications, contact electric signal for 

more information.

See next subject for tube replacement.

VI

.

2

 

 

Replacing the tubes

6ba6/5749/6k4p

ecc81/12at7

6h2p

6h30

 

To remove a tube, press the screening can down

and twist anti-clockwise, when it will spring out. 

Then remove the tube by pulling upwards, 

possibly using a cloth if it’s still hot. Take care 

not to bend the pins when putting back in.

Summary of Contents for MMXV AD

Page 1: ...User manual Delta Transconductance band Compressor Electric Signal MMXV AD Electric Signal 2016 Revision Alpha...

Page 2: ...Delta Transconductance band Compressor User manual Electric Signal MMXV AD Serial number a priori Line voltage...

Page 3: ...output 18 4 1 Main mute 4 2 Main system bypass 4 3 Main input V 1 Filter block chain 19 2 Bode plot s of filter settings 2 1 high to mid 6dB oct mid to low 6dB oct 21 2 2 high to mid 12dB oct mid to...

Page 4: ...only a switch in the chain we try to achieve to give the engineer the maximum potential by providing him the relevant choices It is tough to vocolise however Arthur Shoppenhauwer writes in the world...

Page 5: ...While doing so check for compromised vacuum and broken glass Use short XLR cables for input output where pin 1 ground shield pin 2 positive phase hot pin 3 negative phase cold Use the power inlet cab...

Page 6: ...ment panel Behind the measurement panel there are two 9pins d sub sockets with the numbering of pins While tubes age their conductance decrease and therefore the gain reduction meters will indicate co...

Page 7: ...ons and the axiom a shorter signal pad is in most cases better the Delta Transconductance band Compressor uses more than 100 signal relays and they may give a light clicking sound if a control is used...

Page 8: ...leds Balance measurement Meter zero Balance Attack time Release time 0 1 0 6 0 3 0 8 1 0 1 5 4 0 34 20 50 100 130 0 01 0 04 0 05 0 08 0 10 0 13 0 2 1 2 0 5 1 5 0 8 1 8 level High mute Recovery gain Th...

Page 9: ...ther IV 2 1 Input Gain IV 2 2 Attack time IV 2 4 Threshold IV 2 3 Release time IV 2 5 Recovery gain Behold the following visual This is a manipulated image from the front panel the control main and th...

Page 10: ...lowers the meters may drop However the bias can be recalibrated if this occurs see III 3 IV 2 6 Stereo link Mutes the channel IV 2 7 Mute IV 3 Gain reduction meters 24 position rotary switch controls...

Page 11: ...k 1 2k 1 5k 1 8k 2 3k 3 0k 3 8k 4 8k 6 2k 8 0k 10k 14k Audio signal Control signal Filter I O 2nd order 2nd order 1st order 1st order 1st order 1st order 2nd order 2nd order Mid output High output Low...

Page 12: ...hp on lp off high to mid hp on lp off mid to low hp on lp on high to mid hp on lp off mid to low hp on lp off high to mid hp on lp off mid to low hp off lp on high to mid hp on lp off mid to low hp o...

Page 13: ...off lp off high to mid hp off lp on mid to low hp on lp on high to mid hp off lp on mid to low hp on lp off high to mid hp off lp on mid to low hp off lp on high to mid hp off lp on mid to low hp off...

Page 14: ...id hp on lp off mid to low hp off lp on high to mid hp on lp off mid to low hp off lp off high to mid hp off lp on mid to low hp on lp on high to mid hp off lp on mid to low hp on lp off high to mid h...

Page 15: ...lp off mid to low hp on lp on high to mid hp on lp off mid to low hp on lp off high to mid hp on lp off mid to low hp off lp on high to mid hp on lp off mid to low hp off lp off high to mid hp off lp...

Page 16: ...same material and later mixed together Often a heavy compressed signal is combined with an ligtly or uncompressed signal The filter bypass function makes it possible to change from a band compressor...

Page 17: ...l Elecric The two 6h30 for the output need to be matched triodes The Delta Transconductance band compressor comes with two russian milspec 6h2p er responsible for mixing if desired to use an european...

Page 18: ...cations Input impedance Output impedance Signal to noise Power consumption Weight Operating voltage THD Frequency responce Attack time Release time VII 2 Warrenty The unit comes with a 24 month warran...

Page 19: ...ry as the emitted charge carriers move away from the emitter and finally the emitter will be in the same state as it was before emission The classical example of thermionic emission is the emission of...

Page 20: ...on on link on mono off off mute 6 0 01 0 04 0 05 0 08 0 10 0 13 0 2 1 2 0 5 1 5 0 8 1 8 0 1 0 6 0 3 0 8 1 0 1 5 4 0 34 20 50 100 130 9 6 3 3 0 12 3 0 6 9 3 on on link on mono off off mute 6 0 01 0 04...

Reviews: